- Multi-parameter Water Analyzer
- Single-Parameter Water Aalyzer
- DO Sensor
- Trace DO Sensor
- CO₂ Sensor
- COD Sensor
- EC TDS Sensor
- Salinity EC TDS Sensor
- TSS Sensor
- Turbidity Sensor
- PH Sensor
- ORP
- Ion Selective Sensor
- Ammonia Nitrogen Sensor
- Oil in Water Sensor
- Blue-Green Algae Sensor
- Chlorophyll Sensor
- Residual Chlorine Sensor
- Marine Current Sensor
90° Infrared Light Scattering Turbidity Sensor for Water Quality Analysis - Durable China Suppliers & Factory Solution
| Product Name | Turbidity Sensor |
| Measurement Method | 90° Light Scattering Method |
| Range | 0–100 NTU / 0–3000 NTU |
| Accuracy | Less than ±10% of measured value (depending on sludge homogeneity) or 10 mg/L, whichever is greater |
| Power | 9–24 VDC (Recommended: 12 VDC) |
| Size | 50 mm × 200 mm |
| Material | 316L Stainless Steel |
| Output | RS-485, MODBUS Protocol |
Adhering to optical engineering standards, the sensor ensures high-precision turbidity measurements by minimizing chromaticity interference and ambient light effects.
Advanced fiber-optic light paths and temperature compensation algorithms enable stable performance under direct sunlight, ideal for outdoor or open-air installations.
With a <5 cm proximity requirement to obstacles and minimal calibration volume (30 mL), it simplifies integration into tanks, pipelines, or portable systems.
The 316L stainless steel housing withstands aggressive chemical environments, ensuring long-term reliability in industrial or marine applications.
Proprietary software algorithms and precision optics reduce signal drift, guaranteeing consistent accuracy across fluctuating conditions.
Monitor turbidity in real time to optimize filtration, sedimentation, and discharge compliance.
Deploy in rivers, lakes, or reservoirs to track sediment levels and pollution events.
Ensure water clarity by detecting suspended particles in treatment facilities or distribution networks.
Maintain optimal water quality for aquatic health by preventing excessive turbidity.
Integrate into chemical or pharmaceutical processes to ensure product quality and regulatory adherence.
Monitor runoff water turbidity to meet environmental regulations and mitigate risks of sediment-related pollution in surrounding ecosystems.
Support scientific studies on water clarity, sediment dynamics, and pollution modeling with high-precision turbidity data.
| Parameter | Model | Range | Accuracy |
| DO Sensor | LMS-DO10B | 0–20 mg/L, 0–60℃ | ±0.1–0.3 mg/L |
| DO Sensor | LMS-DO10C | 0–20 mg/L, 0–60℃ | ±0.3 mg/L |
| Trace DO Sensor | LMS-TDO100 | 0–2000 ppb, 0–50℃ | ±1 ppb |
| PH Sensor | LMS-PH100 | 0–14 pH | ±0.02 pH |
| ORP Sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV |
| EC/TDS Sensor | LMS-TDS102 | CT: 0–9999 uS/cm; 0–100 mS/cm; TDS: 0–10000 ppm | ±2.5% FS |
| Salinity/EC/TDS Sensor | LMS-SAL104 | Conductivity: 0.1–500 mS/cm; TDS: 0–60000 ppm; Salinity: 0–500.00 ppt | ±1.5% FS |
| COD Sensor | LMS-COD100 | COD: 0.1–1500 mg/L; TOC: 0.1–750 mg/L; BOD: 0.1–900 mg/L; Turbidity: 0.1–4000 NTU; Temp: 0–50℃ | ±5% equiv. KHP; Temp: ±0.5℃ |
| TSS Sensor | LMS-TSS100 | 0–50000 mg/L / 0–120000 mg/L | ±10% FS or 10 mg/L |
| Turbidity Sensor | LMS-TUR10L | 0–100 NTU | ±10% FS or 0.3 NTU |
| Turbidity Sensor | LMS-TUR10H | 0–3000 NTU | ±10% FS or 0.3 NTU |
| CO₂ Sensor | LMS-CO2100 | 2000 PPM / 10000 PPM / 50000 PPM | ±5% FS |
| Ammonia Nitrogen Sensor | LMS-NH4100 | 0–1000 mg/L | ±5% FS |
| Ion Selective Sensor | LMS-ION100 | 0–1000 mg/L | ±5% FS |
| Oil in Water Sensor | LMS-OIL100 | 0–50 mg/L; 0–5 mg/L | ±3% FS |
| Chlorophyll Sensor | LMS-CHL100 | 0–500 ug/L | ±3% FS |
| Blue-Green Algae Sensor | LMS-BGA100 | 0–2,000,000 cells/mL | ±3% FS |
| Residual Chlorine Sensor | LMS-HCLO100 | 0–20.00 ppm | ±5% FS |
| Marine Current Sensor | LMS-Current100 | Temp: -3℃–45℃; Velocity: 0–500 cm/s; Direction: 0–359.9° | ±0.05℃; ±1 cm/s or ±2%; ±2° |