• instagram (5)
  • 65e82dd72e92827394
  • 65e82dd7a74e048637
  • 65e82dd83039430728
Leave Your Message

90° Infrared Light Scattering Turbidity Sensor for Water Quality - China Suppliers & Factory Equipment

The Turbidity Sensor, designed with cutting-edge technology, employs a 90° infrared light scattering principle for accurate measurements in challenging environments. Ideal for wastewater treatment, environmental monitoring, and industrial applications, this sensor features advanced fiber-optic light paths that minimize ambient light interference, alongside specialized polishing techniques and robust software algorithms. With low drift and a sunlight-compatible design, it performs reliably outdoors and in direct sunlight. This compact sensor requires only 30 mL of standard solution for calibration and maintains a low proximity requirement of less than 5 cm to nearby obstacles. Built from durable 316L stainless steel and equipped with RS-485 MODBUS output, this turbidity sensor guarantees long-lasting reliability and precision, making it the top choice for buyers seeking quality products from trusted China suppliers and manufacturers. Produce consistent results in harsh conditions with this state-of-the-art turbidity sensor from a leading factory.

    Product Parameters
    Product Name Turbidity Sensor
    Measurement Method 90° light scattering method
    Range 0–100 NTU / 0–3000 NTU
    Accuracy Less than ±10% of measured value (depending on sludge homogeneity) or 10 mg/L, whichever is greater
    Power 9–24 VDC (Recommend 12 VDC)
    Size 50 mm × 200 mm
    Material 316L Stainless Steel
    Output RS-485, MODBUS Protocol
    Product Features
    90° Infrared Scattering Technology
    Adhering to optical engineering standards, the sensor ensures high-precision turbidity measurements by minimizing chromaticity interference and ambient light effects.
    Sunlight-Resistant Design
    Advanced fiber-optic light paths and temperature compensation algorithms enable stable performance under direct sunlight, ideal for outdoor or open-air installations.
    Compact & Low Maintenance
    With a <5 cm proximity requirement to obstacles and minimal calibration volume (30 mL), it simplifies integration into tanks, pipelines, or portable systems.
    Anti-Corrosion Construction
    The 316L stainless steel housing withstands aggressive chemical environments, ensuring long-term reliability in industrial or marine applications.
    Drift-Free Performance
    Proprietary software algorithms and precision optics reduce signal drift, guaranteeing consistent accuracy across fluctuating conditions.
    Application
    Wastewater Treatment Plants
    Monitor turbidity in real time to optimize filtration, sedimentation, and discharge compliance.
    Environmental Monitoring
    Deploy in rivers, lakes, or reservoirs to track sediment levels and pollution events.
    Drinking Water Systems
    Ensure water clarity by detecting suspended particles in treatment facilities or distribution networks.
    Aquaculture Management
    Maintain optimal water quality for aquatic health by preventing excessive turbidity.
    Industrial Process Control
    Integrate into chemical or pharmaceutical processes to ensure product quality and regulatory adherence.
    Mining & Construction
    Monitor runoff water turbidity to meet environmental regulations and mitigate risks of sediment-related pollution in surrounding ecosystems.
    Research & Laboratories
    Support scientific studies on water clarity, sediment dynamics, and pollution modeling with high-precision turbidity data.
    application
    Digital RS485 Water Quality Sensors Technical Data
    Parameter Model Range Accuracy
    DO Sensor LMS-DO10B 0–20 mg/L, 0–60℃ ±0.1–0.3 mg/L
    DO Sensor LMS-DO10C 0–20 mg/L, 0–60℃ ±0.3 mg/L
    Trace DO Sensor LMS-TDO100 0–2000 ppb, 0–50℃ ±1 ppb
    PH Sensor LMS-PH100 0–14 pH ±0.02 pH
    ORP Sensor LMS-ORP100 ±1000.0 mV ±0.2 mV
    EC/TDS Sensor LMS-TDS102 CT: 0–9999 uS/cm; 0–100 mS/cm;
    TDS: 0–10000 ppm
    ±2.5% FS
    Salinity/EC/TDS Sensor LMS-SAL104 Conductivity: 0.1–500 mS/cm
    TDS: 0–60000 ppm
    Salinity: 0–500.00 ppt
    ±1.5% FS
    COD Sensor LMS-COD100 COD: 0.1–1500 mg/L
    TOC: 0.1–750 mg/L
    BOD: 0.1–900 mg/L
    Turbidity: 0.1–4000 NTU
    Temperature: 0–50℃
    ±5% equiv. KHP
    Temperature: ±0.5℃
    TSS Sensor LMS-TSS100 0–50000 mg/L / 0–120000 mg/L ±10% FS or 10 mg/L
    Turbidity Sensor LMS-TUR10L 0–100 NTU ±10% FS or 0.3 NTU
    Turbidity Sensor LMS-TUR10H 0–3000 NTU ±10% FS or 0.3 NTU
    CO2 Sensor LMS-CO2100 2000 PPM / 10000 PPM / 50000 PPM ±5% FS
    Ammonia Nitrogen Sensor LMS-NH4100 0–1000 mg/L ±5% FS
    Ion Selective Sensor LMS-ION100 0–1000 mg/L ±5% FS
    Oil in Water Sensor LMS-OIL100 0–50 mg/L; 0–5 mg/L ±3% FS
    Chlorophyll Sensor LMS-CHL100 0–500 ug/L ±3% FS
    Blue-Green Algae Sensor LMS-BGA100 0–2,000,000 cells/ml ±3% FS
    Residual Chlorine Sensor LMS-HCLO100 0–20.00 ppm ±5% FS
    Marine Current Sensor LMS-Current100 Temperature: -3℃ – 45℃
    Velocity of flow: 0–500 cm/s
    Flow direction: 0–359.9°
    ±0.05℃
    ±1 cm/s or ±2%
    ±2°
    more products
    Frequently Asked Questions
    What measurement method does the turbidity sensor use?
    The turbidity sensor uses the 90° infrared light scattering method, which measures the intensity of light scattered at a right angle to the incident beam. This approach minimizes interference from color and ambient light, providing highly accurate turbidity readings.
    What are the available measurement ranges for this turbidity sensor?
    The sensor is available in two range models: LMS-TUR10L covers 0–100 NTU for low-turbidity applications such as drinking water, while LMS-TUR10H covers 0–3000 NTU for higher-turbidity environments such as wastewater treatment or industrial processes.
    What communication protocol does the turbidity sensor support?
    The sensor outputs data via RS-485 using the MODBUS protocol, making it easy to integrate with PLCs, data loggers, water quality controllers, and SCADA systems commonly used in industrial and environmental monitoring applications.
    Is the turbidity sensor suitable for outdoor or sunlight-exposed installations?
    Yes. The sensor features a sunlight-resistant design with advanced fiber-optic light paths and temperature compensation algorithms, enabling stable and reliable performance even under direct sunlight or in open-air outdoor environments.
    What material is the sensor housing made of, and is it suitable for harsh environments?
    The sensor housing is constructed from 316L stainless steel, which provides excellent resistance to corrosion, chemicals, and saltwater. This makes it highly suitable for demanding environments including industrial wastewater, marine applications, and chemical processing facilities.
    Can the turbidity sensor be used alongside other water quality sensors in the same system?
    Absolutely. The sensor is part of a comprehensive RS-485 MODBUS digital sensor lineup that includes DO, pH, ORP, EC/TDS, COD, TSS, ammonia nitrogen, chlorophyll, and many more parameters. Multiple sensors can be connected on the same RS-485 bus for multi-parameter water quality monitoring systems.

    Leave Your Message