- Multi-parameter Water Analyzer
- Single-Parameter Water Aalyzer
- DO Sensor
- Trace DO Sensor
- CO₂ Sensor
- COD Sensor
- EC TDS Sensor
- Salinity EC TDS Sensor
- TSS Sensor
- Turbidity Sensor
- PH Sensor
- ORP
- Ion Selective Sensor
- Ammonia Nitrogen Sensor
- Oil in Water Sensor
- Blue-Green Algae Sensor
- Chlorophyll Sensor
- Residual Chlorine Sensor
- Marine Current Sensor
0102030405
China 4G Module and Cloud Platform for Multi-Parameter Water Quality Analyzer - Trusted Suppliers and Factory Solutions
Product Parameters
ⓘ The model, appearance, configuration and parameters of the 4G module will be flexibly adjusted according to different requirements. Please inform us of your specific needs, and we will tailor a satisfactory customized solution for you.
Product Features
- ① Supports 220V AC input or customized 110V input
- ② Operating environment: Temperature -10 to 60°C, relative humidity ≤ 95% RH
- ③ Built-in 4G communication module and antenna
- ④ Interface type: RS485
- ⑤ Memory module: Data can be exported via USB flash drive
-
⑥
Customizable 4G Module:
Corresponding 4G modules can be configured based on different user requirements, and it enables uninterrupted real-time monitoring by accessing the cloud system via mobile phones and computers.
Application
More Products
Digital RS485 Water Quality Sensors Technical Data
| No. | Picture | Product Name | Model | Range | Accuracy | Resolution |
|---|---|---|---|---|---|---|
| 1 | ![]() |
DO sensor | LMS-DO10B | 0-20mg/L, 0-60℃ | ±0.1-0.3mg/L | 0.01mg/L |
| 2 | ![]() |
DO sensor | LMS-DO10C | 0-20mg/L, 0-60℃ | ±0.3mg/L | 0.01mg/l |
| 3 | ![]() |
Trace DO sensor | LMS-TDO100 | 0-2000ppb, 0-50℃ | ±1ppb | 1ppb |
| 4 | ![]() |
PH sensor | LMS-PH100 | 0-14pH | ±0.02pH | 0.01pH |
| 5 | ![]() |
ORP sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV | 0.1mV |
| 6 | ![]() |
EC/TDS sensor | LMS-TDS102 | CT: 0-9999uS/cm; 0-100mS/cm; TDS: 0-10000ppm | ±2.5%FS | 1uS/cm, 0.01mS/cm, 1ppm |
| 7 | ![]() |
Salinity/EC/TDS sensor | LMS-SAL104 | Conductivity: 0.1-500 mS/cm; TDS: 0-60000ppm; Salinity: 0-500.00ppt | ±1.5%FS | 1uS/cm, 0.01mS/cm, 1ppm, 0.01ppt |
| 8 | ![]() |
COD sensor | LMS-COD100 | COD: 0.1-1500mg/L; TOC: 0.1-750mg/L; BOD: 0.1-900mg/L; Turbidity: 0.1-4000NTU; Temp: 0-50℃ | ±5% equiv.KHP; Temp: ±0.5℃ | 0.01mg/L equiv.KHP |
| 9 | ![]() |
TSS sensor | LMS-TSS100 | 0-50000mg/L / 0-120000mg/L | ±10%FS or 10 mg/L | 0.1mg/L or 1mg/L |
| 10 | ![]() |
Turbidity sensor | LMS-TUR10L | 0-100NTU | ±10%FS or 0.3 NTU | 0.01NTU |
| 11 | ![]() |
Turbidity sensor | LMS-TUR10H | 0-3000NTU | ±10%FS or 0.3 NTU | 0.01NTU |
| 12 | ![]() |
CO2 sensor | LMS-CO2100 | 2000PPM / 10000PPM / 50000PPM | ±5%FS | 1ppm |
| 13 | ![]() |
Ammonia Nitrogen sensor | LMS-NH4100 | 0-1000 mg/L | ±5%FS | — |
| 14 | ![]() |
Ion Selective sensor | LMS-ION100 | 0-1000 mg/L | ±5%FS | — |
| 15 | ![]() |
Oil in Water sensor | LMS-OIL100 | 0-50 mg/L; 0-5 mg/L | ±3%FS | 0.01ppm |
| 16 | ![]() |
Chlorophyll sensor | LMS-CHL100 | 0-500ug/L | ±3%FS | 0.1ug/L |
| 17 | ![]() |
Blue-Green Algae sensor | LMS-BGA100 | 0-2,000,000 cells/ml | ±3%FS | — |
| 18 | ![]() |
Residual Chlorine sensor | LMS-HCLO100 | 0 - 20.00 ppm | ±5%FS | 0.001 / 0.01ppm |
| 19 | ![]() |
Marine Current sensor | LMS-Current100 | Temperature: -3℃ - 45℃; Velocity: 0-500 cm/s; Direction: 0-359.9° | ±0.05℃; ±1 cm/s or ±2%; ±2° | Temp: 0.001℃; Velocity: 0.1 cm/s; Direction: 0.1° |
Water Quality Analyzer Equipment
| No. | Picture | Product Name | Model | Size | Power | Display Output |
|---|---|---|---|---|---|---|
| 20 | ![]() |
Portable DO Analyzer | LMS-PA100 | 100mm × 204mm | <0.5W; Power supply 7.5V, 5 batteries | LCD display screen |
| 21 | ![]() |
Multi-parameter Portable Water Analyzer | LMS-PA100P | 220mm × 120mm × 100mm | Rechargeable lithium battery with 220V DC charging adapter | LCD display screen |
| 22 | ![]() |
Multi-parameter Touch-screen Online Analyzer | LMS-OA200T | 180mm × 230mm × 100mm | AC power supply: 220 VAC | 7-inch touch screen |
Frequently Asked Questions (FAQ)
Q
What input voltage does the 4G module support?
The 4G module supports 220V AC input as standard. A customized 110V input version is also available upon request to meet different regional power supply requirements.
Q
What communication interface does the 4G module use?
The 4G module uses an RS485 interface, which is widely compatible with most industrial water quality sensors and monitoring equipment for reliable data transmission.
Q
Can the 4G module enable remote real-time monitoring?
Yes. The built-in 4G communication module and antenna allow the device to connect to a cloud system, enabling uninterrupted real-time monitoring via both mobile phones and computers from anywhere.
Q
How can data be exported from the 4G module?
The device is equipped with a memory module that allows data to be conveniently exported using a USB flash drive, making it easy to archive and analyze historical monitoring data offline.
Q
What are the operating environment requirements for the 4G module?
The 4G module is designed to operate in temperatures ranging from -10°C to 60°C, with a relative humidity of ≤ 95% RH, making it suitable for a wide range of industrial and outdoor water quality monitoring environments.
Q
Can the 4G module be customized to work with different water quality sensors?
Absolutely. The model, appearance, configuration, and parameters of the 4G module can be flexibly adjusted based on specific user requirements. It is compatible with a wide range of RS485 digital water quality sensors including DO, pH, ORP, EC/TDS, turbidity, COD, and many more.