• instagram (5)
  • 65e82dd72e92827394
  • 65e82dd7a74e048637
  • 65e82dd83039430728
Leave Your Message

China Aquaculture Fluorescence Dissolved Oxygen Meter DO Sensor Probe - Suppliers & Factory Direct Quality Solutions

The LuminSens DO Sensor Type C is the perfect solution for aquaculture applications in China, designed specifically for challenging environments. This advanced sensor employs cutting-edge fluorescence lifetime technology to provide accurate and reliable dissolved oxygen (DO) measurements without the drawbacks of oxygen consumption or flow limitations. Manufactured by top suppliers in the industry, its bacteriostatic and scratch-resistant fluorescent film offers superior durability and performance even in harsh water conditions, With a built-in temperature sensor and an impressive rapid response time of greater than 120 seconds, this sensor ensures consistent accuracy within ±0.3mg/L, making it ideal for continuous monitoring in aquaculture. By preventing fish suffocation and optimizing aquatic health, it significantly enhances farming efficiency. Trust the LuminSens DO Sensor Type C, produced in a state-of-the-art factory, to meet all your monitoring needs in the dynamic field of aquaculture in China

    Product Parameters
    Product Name DO sensor type C
    Product Description Special for aquaculture online, suitable for harsh water bodies; Fluorescent film has the advantages of bacteriostasis, scratch resistance, and good anti-interference ability. The temperature is built in.
    Respond Time > 120s
    Accuracy ±0.3mg/L
    Range 0~50℃、0~20mg⁄L
    Temperature Accuracy <0.3℃
    Working Temperature 0~40℃
    Storage Temperature -5~70℃
    Size φ32mm*170mm
    Power 9-24VDC(Recommend 12 VDC)
    Material Polymer Plastic
    Output RS-485, MODBUS protocol
    Product Features
    • 🐟
      ① Specialized Aquaculture Design: Tailored for online monitoring in harsh aquaculture environments, featuring a durable fluorescent film that resists bacterial growth, scratches, and external interference, ensuring long-term reliability in polluted or high-biomass water.
    • 💡
      ② Advanced Fluorescence Technology: Utilizes fluorescence lifetime measurement to deliver stable, precise dissolved oxygen data without oxygen consumption or flow rate limitations, outperforming traditional electrochemical methods.
    • 🎯
      ③ Reliable Performance: Maintains high accuracy (±0.3mg/L) and consistent operation within a wide temperature range (0-40°C), with a built-in temperature sensor for automatic compensation.
    • 🔧
      ④ Low Maintenance: Eliminates the need for electrolyte replacement or frequent calibration, reducing operational costs and downtime.
    • 🔌
      ⑤ Easy Integration: Supports RS-485 and MODBUS protocol for seamless connectivity with existing monitoring systems, compatible with 9-24VDC power supplies for flexible installation.
    Application
    Aquaculture Farming

    Ideal for continuous dissolved oxygen tracking in ponds, tanks, and recirculating aquaculture systems (RAS), where harsh water conditions—such as high organic matter, algae blooms, or chemical treatments—are common. The sensor's bacteriostatic and anti-scratch film ensures reliable performance in these challenging environments, helping farmers maintain optimal oxygen levels to prevent fish stress, suffocation, and disease. By providing real-time data, it enables proactive management of aeration systems, enhancing aquatic health and improving aquaculture efficiency.

    This model is particularly suited for large-scale fish farms, shrimp hatcheries, and aquaculture research facilities, where accurate and durable monitoring is critical for sustainable production. Its robust design and advanced technology make it a trusted solution for ensuring water quality and maximizing yield in intensive aquaculture operations.

    Wastewater Management

    Tracks oxygen levels in industrial or agricultural runoff with high particulate content.

    Research and Environmental Monitoring

    Ideal for long-term studies in challenging natural water bodies, such as estuaries or polluted lakes.

    application
    Digital RS485 Water Quality Sensors Technical Data
    Digital RS485 Water Quality Sensors Technical Data
    No. Picture Product Name Model Range Accuracy Resolution
    1 Digital RS4851 DO sensor LMS-DO10B 0-20mg/L, 0-60℃ ±0.1-0.3mg/L 0.01mg/L
    2 Digital RS4852 DO sensor LMS-DO10C 0-20mg/L, 0-60℃ ±0.3mg/L 0.01mg/l
    3 Digital RS4853 Trace DO sensor LMS-TDO100 0-2000ppb, 0-50℃ ±1ppb 1ppb
    4 Digital RS4854 PH sensor LMS-PH100 0-14pH ±0.02pH 0.01pH
    5 Digital RS4854 ORP sensor LMS-ORP100 ±1000.0 mV ±0.2 mV 0.1mV
    6 Digital RS4856 EC/TDS sensor LMS-TDS102 CT: 0-9999uS/cm; 0-100mS/cm; TDS: 0-10000ppm ±2.5%FS 1uS/cm, 0.01mS/cm, 1ppm
    7 Digital RS4857 Salinity/EC/TDS sensor LMS-SAL104 Conductivity: 0.1-500 mS/cm; TDS: 0-60000ppm; Salinity: 0-500.00ppt ±1.5%FS 1uS/cm, 0.01mS/cm, 1ppm, 0.01ppt
    8 Digital RS4858 COD sensor LMS-COD100 COD: 0.1-1500mg/L; TOC: 0.1-750mg/L; BOD: 0.1-900mg/L; Turbidity: 0.1-4000NTU; Temp: 0-50℃ ±5% equiv.KHP; Temp: ±0.5℃ 0.01mg/L equiv.KHP
    9 Digital RS4859 TSS sensor LMS-TSS100 0-50000mg/L / 0-120000mg/L ±10%FS or 10 mg/L 0.1mg/L or 1mg/L
    10 Digital RS48510 Turbidity sensor LMS-TUR10L 0-100NTU ±10%FS or 0.3 NTU 0.01NTU
    11 Digital RS48510 Turbidity sensor LMS-TUR10H 0-3000NTU ±10%FS or 0.3 NTU 0.01NTU
    12 Digital RS48512 CO2 sensor LMS-CO2100 2000PPM / 10000PPM / 50000PPM ±5%FS 1ppm
    13 Digital RS48513 Ammonia Nitrogen sensor LMS-NH4100 0-1000 mg/L ±5%FS
    14 Digital RS48513 Ion Selective sensor LMS-ION100 0-1000 mg/L ±5%FS
    15 Digital RS48510 Oil in Water sensor LMS-OIL100 0-50 mg/L; 0-5 mg/L ±3%FS 0.01ppm
    16 Digital RS48510 Chlorophyll sensor LMS-CHL100 0-500ug/L ±3%FS 0.1ug/L
    17 Digital RS48510 Blue-Green Algae sensor LMS-BGA100 0-2,000,000 cells/ml ±3%FS
    18 Digital RS48518 Residual Chlorine sensor LMS-HCLO100 0 - 20.00 ppm ±5%FS 0.001 / 0.01ppm
    19 Digital RS48519 Marine Current sensor LMS-Current100 Temperature: -3℃ - 45℃; Velocity: 0-500 cm/s; Direction: 0-359.9° ±0.05℃; ±1 cm/s or ±2%; ±2° Temp: 0.001℃; Velocity: 0.1 cm/s; Direction: 0.1°
    Water Quality Analyzer Equipment
    No. Picture Product Name Model Size Power Display Output
    20 Digital RS48520 Portable DO Analyzer LMS-PA100 100mm*204mm <0.5W; 7.5V, 5 batteries LCD display screen
    21 Digital RS48521 Multi-parameter Portable Water Analyzer LMS-PA100P 220mm*120mm*100mm Rechargeable lithium battery with 220V DC charging adapter LCD display screen
    22 Digital RS48522 Multi-parameter Touch-screen Online Analyzer LMS-OA200T 180mm×230mm×100mm AC power supply: 220 VAC 7-inch touch screen
    more products
    Frequently Asked Questions (FAQ)
    What makes the DO Sensor Type C suitable for aquaculture environments?
    The DO Sensor Type C is specifically designed for harsh aquaculture conditions. Its fluorescent film features bacteriostatic properties, scratch resistance, and strong anti-interference capability, making it highly durable in water bodies with high organic matter, algae, or chemical treatments. The built-in temperature sensor also ensures automatic compensation for accurate readings.
    How does fluorescence technology differ from traditional electrochemical DO measurement?
    Unlike traditional electrochemical sensors, fluorescence-based measurement uses fluorescence lifetime detection, which does not consume oxygen during measurement and is not affected by flow rate. This results in more stable, accurate, and long-lasting performance with minimal maintenance requirements.
    What communication protocol does the DO Sensor Type C support?
    The sensor supports RS-485 communication with MODBUS protocol, making it easy to integrate with a wide range of existing water quality monitoring systems, PLCs, and data loggers. It is compatible with power supplies ranging from 9 to 24VDC.
    How often does the DO Sensor Type C require calibration or maintenance?
    One of the key advantages of this sensor is its low maintenance design. It does not require electrolyte replacement or frequent calibration, significantly reducing operational costs and system downtime compared to traditional polarographic or galvanic sensors.
    Can this sensor be used for applications other than aquaculture?
    Yes. While optimized for aquaculture, the DO Sensor Type C is also well-suited for wastewater management (tracking oxygen in industrial or agricultural runoff with high particulate content) and environmental research applications such as monitoring estuaries, polluted lakes, or other challenging natural water bodies.
    What is the measurement range and accuracy of the DO Sensor Type C?
    The sensor measures dissolved oxygen in the range of 0–20 mg/L and temperature from 0–50℃. It offers an accuracy of ±0.3 mg/L for dissolved oxygen and less than 0.3℃ for temperature, with a response time greater than 120 seconds for stable and reliable readings.