Product Parameters
| Product Name | Dissolved Carbon Dioxide Analyzer in Water |
| Range | 2000PPM / 10000PPM / 50000PPM range optional |
| Accuracy | ≤ ±5% FS |
| Operating Voltage | Sensors: DC 12~24V; Analyzer: Rechargeable lithium battery with 220V to DC charging adapter |
| Material | Polymer Plastic |
| Working Current | 60mA |
| Output Signal | UART / Analog Voltage / RS485 |
| Cable Length | 5m, can be extended according to user need |
| Application | Tap water treatment, swimming pool water quality monitoring, and industrial wastewater treatment. |
Product Features
1
Precision Measurement Technology
NDIR Dual-Beam Compensation: Minimizes environmental interference for stable readings.
Self-Cleaning Membrane Design: PTFE membrane with convection diffusion accelerates gas exchange while preventing contamination.
2
Intelligent Calibration & Flexibility
Multi-Point Calibration: Supports zero, span, and ambient air adjustments via software or hardware (MCDL pin).
Universal Compatibility: Seamless integration with PLCs, SCADA, and IoT platforms through Modbus-RTU protocol.
3
Robust & Maintenance-Friendly
Modular Waterproof Structure: Detachable sensor head simplifies cleaning and membrane replacement.
Extended Durability: Corrosion-resistant materials ensure 5+ years lifespan in high-humidity or saline environments.
4
Cross-Industry Applications
Water Management: Optimize CO₂ levels in aquaculture, hydroponics, and municipal water treatment.
Industrial Compliance: Monitor emissions in wastewater plants to meet EPA/ISO standards.
Beverage Production: Real-time carbonation tracking for beer, soda, and sparkling water quality control.
Application
Water Treatment Plants
Real-time monitoring of dissolved CO₂ concentrations enables precise optimization of coagulant dosing ratios while inhibiting metal pipeline corrosion risks in water distribution networks.
Agriculture & Aquaculture
Maintain 300–800ppm CO₂ levels to enhance photosynthetic efficiency in hydroponic greenhouses and ensure optimal gas exchange for aquatic organisms in recirculating aquaculture systems (RAS).
Environmental Monitoring
Deploy in rivers, lakes, or wastewater treatment plants to track CO₂ emissions and ensure regulatory compliance.
Beverage Production
Quantify dissolved CO₂ within 2,000–5,000ppm range to verify carbonation consistency during bottling processes, ensuring sensory quality compliance with food safety standards.
More Products
| Digital RS485 Water Quality Sensors Technical Data | ||||||
| No. | Picture | Product Name | Model | Range | Accuracy | Resolution |
| 1 | ![]() |
DO sensor | LMS-DO10B | 0-20mg/L, 0-60℃ | ±0.1-0.3mg/L | 0.01mg/L |
| 2 | ![]() |
DO sensor | LMS-DO10C | 0-20mg/L, 0-60℃ | ±0.3mg/L | 0.01mg/l |
| 3 | ![]() |
Trace DO sensor | LMS-TDO100 | 0-2000ppb, 0-50℃ | ±1ppb | 1ppb |
| 4 | ![]() |
PH sensor | LMS-PH100 | 0-14pH | ±0.02pH | 0.01pH |
| 5 | ![]() |
ORP sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV | 0.1mV |
| 6 | ![]() |
EC/TDS sensor | LMS-TDS102 | CT: 0-9999uS/cm; 0-100mS/cm; TDS: 0-10000ppm |
±2.5%FS | 1uS/cm, 0.01mS/cm, 1ppm |
| 7 | ![]() |
Salinity/EC/TDS sensor | LMS-SAL104 | Conductivity: 0.1-500 mS/cm TDS: 0-60000ppm Salinity: 0-500.00ppt |
±1.5%FS | 1uS/cm, 0.01mS/cm, 1ppm, 0.01ppt |
| 8 | ![]() |
COD sensor | LMS-COD100 | COD: 0.1-1500mg/L TOC: 0.1-750mg/L BOD: 0.1-900mg/L Turbidity: 0.1-4000NTU Temp: 0-50℃ |
±5% equiv.KHP Temp: ±0.5℃ |
0.01mg/L equiv.KHP |
| 9 | ![]() |
TSS sensor | LMS-TSS100 | 0-50000mg/L / 0-120000mg/L | ±10%FS or 10 mg/L | 0.1mg/L or 1mg/L |
| 10 | ![]() |
Turbidity sensor | LMS-TUR10L | 0-100NTU | ±10%FS or 0.3 NTU | 0.01NTU |
| 11 | ![]() |
Turbidity sensor | LMS-TUR10H | 0-3000NTU | ±10%FS or 0.3 NTU | 0.01NTU |
| 12 | ![]() |
CO2 sensor | LMS-CO2100 | 2000PPM / 10000PPM / 50000PPM | ±5%FS | 1ppm |
| 13 | ![]() |
Ammonia Nitrogen sensor | LMS-NH4100 | 0-1000 mg/L | ±5%FS | — |
| 14 | ![]() |
Ion Selective sensor | LMS-ION100 | 0-1000 mg/L | ±5%FS | — |
| 15 | ![]() |
Oil in Water sensor | LMS-OIL100 | 0-50 mg/L; 0-5 mg/L | ±3%FS | 0.01ppm |
| 16 | ![]() |
Chlorophyll sensor | LMS-CHL100 | 0-500ug/L | ±3%FS | 0.1ug/L |
| 17 | ![]() |
Blue-Green Algae sensor | LMS-BGA100 | 0-2,000,000 cells/ml | ±3%FS | — |
| 18 | ![]() |
Residual Chlorine sensor | LMS-HCLO100 | 0-20.00 ppm | ±5%FS | 0.001 / 0.01ppm |
| 19 | ![]() |
Marine Current sensor | LMS-Current100 | Temperature: -3℃ ~ 45℃ Velocity: 0-500 cm/s Direction: 0-359.9° |
±0.05℃ ±1 cm/s or ±2% ±2° |
Temp: 0.001℃ Velocity: 0.1 cm/s Direction: 0.1° |
| Water Quality Analyzer Equipment | ||||||
| No. | Picture | Product Name | Model | Size | Power | Display Output |
| 20 | ![]() |
Portable DO Analyzer | LMS-PA100 | 100mm × 204mm | <0.5W; Power supply 7.5V, 5 batteries | LCD display screen |
| 21 | ![]() |
Multi-parameter Portable Water Analyzer | LMS-PA100P | 220mm × 120mm × 100mm | Rechargeable lithium battery with 220V to DC charging adapter | LCD display screen |
| 22 | ![]() |
Multi-parameter Touch-screen Online Analyzer | LMS-OA200T | 180mm × 230mm × 100mm | AC power supply: 220 VAC | 7-inch touch screen |
Frequently Asked Questions
What measurement ranges are available for the Dissolved CO₂ Analyzer?
The analyzer offers three selectable ranges: 2000 PPM, 10000 PPM, and 50000 PPM, making it suitable for a wide variety of water quality monitoring applications from drinking water to industrial wastewater.
What communication protocols does the CO₂ sensor support?
The sensor supports UART, analog voltage output, and RS485 (Modbus-RTU protocol), enabling seamless integration with PLCs, SCADA systems, and IoT platforms.
How does the NDIR dual-beam technology improve measurement accuracy?
NDIR (Non-Dispersive Infrared) dual-beam compensation technology minimizes interference from environmental factors such as temperature fluctuations and humidity, ensuring consistently stable and reliable CO₂ readings.
How often does the sensor membrane need to be replaced?
Thanks to the self-cleaning PTFE membrane design and modular waterproof structure, maintenance intervals are significantly extended. The detachable sensor head makes membrane replacement straightforward. Under normal operating conditions, the sensor is designed for 5+ years of service life.
Can the cable length be customized for specific installation requirements?
Yes. The standard cable length is 5 meters, but it can be extended according to the user's specific installation needs. Please contact us to discuss custom cable length requirements.
Is the analyzer suitable for use in beverage production environments?
Yes. The analyzer is well-suited for beverage production, capable of quantifying dissolved CO₂ within the 2,000–5,000 ppm range to verify carbonation consistency during bottling processes, ensuring compliance with food safety and sensory quality standards.