- Multi-parameter Water Analyzer
- Single-Parameter Water Aalyzer
- DO Sensor
- Trace DO Sensor
- CO₂ Sensor
- COD Sensor
- EC TDS Sensor
- Salinity EC TDS Sensor
- TSS Sensor
- Turbidity Sensor
- PH Sensor
- ORP
- Ion Selective Sensor
- Ammonia Nitrogen Sensor
- Oil in Water Sensor
- Blue-Green Algae Sensor
- Chlorophyll Sensor
- Residual Chlorine Sensor
- Marine Current Sensor
0102030405
China Portable Fluorescence O2 Sensor - Dissolved Oxygen Meter DO Water Quality Analyzer from Reliable Suppliers & Factory
Product Parameters
| Product Name | DO sensor type B | DO sensor type C |
| Product Description | Suitable for online monitoring of clean water quality. Temperature built-in or external. | Special for aquaculture online, suitable for harsh water bodies; Fluorescent film has the advantages of bacteriostasis, scratch resistance, and good anti-interference ability. The temperature is built in. |
| Respond Time | < 120s | > 120s |
| Accuracy | ±0.1–0.3 mg/L | ±0.3 mg/L |
| Range | 0~50℃、0~20 mg/L | |
| Temperature Accuracy | < 0.3℃ | |
| Working Temperature | 0~40℃ | |
| Storage Temperature | -5~70℃ | |
| Size | φ32mm × 170mm | |
| Power | 9–24 VDC (Recommend 12 VDC) | |
| Material | Polymer Plastic | |
| Output | RS-485, MODBUS protocol | |
Product Features
-
🔬① Advanced Technology: Utilizes fluorescence lifetime technology for accurate, stable, and rapid dissolved oxygen measurement, overcoming limitations of traditional methods.
-
🌊② Diverse Applications: Two models designed for different scenarios — Type B for handheld detection with super-fast and accurate results; Type C for aquaculture online in harsh water bodies, featuring bacteriostatic, scratch-resistant fluorescent film and strong anti-interference ability.
-
⚡③ Fast Response: Type B offers response time <120s, ensuring timely data acquisition for various applications.
-
✅④ Reliable Performance: High accuracy (0.1–0.3 mg/L for Type B, ±0.3 mg/L for Type C) and stable operation within working temperature range of 0–40°C.
-
🔌⑤ Easy Integration: Supports RS-485 and MODBUS protocol for seamless connectivity, with power supply of 9–24 VDC (recommended 12 VDC).
-
📱⑥ User-friendly Operation: With a high-definition LCD screen and plug-and-play functionality. The ergonomic handheld design is lightweight and portable, ensuring efficient performance in outdoor environments.
Application
-
🌿Environmental Monitoring: Ideal for rivers, lakes, and wastewater treatment plants to track pollution levels and compliance.
-
🐟Aquaculture Management: Monitor dissolved oxygen and salinity for optimal aquatic health in fish farms.
-
🏭Industrial Use: Deploy in marine engineering, oil pipelines, or chemical plants to ensure water quality meets safety standards.
Digital RS485 Water Quality Sensors Technical Data
| Digital RS485 Water Quality Sensors Technical Data | ||||||
| No. | Picture | Product Name | Model | Range | Accuracy | Resolution |
| 1 | ![]() |
DO sensor | LMS-DO10B | 0–20 mg/L, 0–60℃ | ±0.1–0.3 mg/L | 0.01 mg/L |
| 2 | ![]() |
DO sensor | LMS-DO10C | 0–20 mg/L, 0–60℃ | ±0.3 mg/L | 0.01 mg/L |
| 3 | ![]() |
Trace DO sensor | LMS-TDO100 | 0–2000 ppb, 0–50℃ | ±1 ppb | 1 ppb |
| 4 | ![]() |
PH sensor | LMS-PH100 | 0–14 pH | ±0.02 pH | 0.01 pH |
| 5 | ![]() |
ORP sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV | 0.1 mV |
| 6 | ![]() |
EC/TDS sensor | LMS-TDS102 | CT: 0–9999 uS/cm; 0–100 mS/cm; TDS: 0–10000 ppm | ±2.5% FS | 1 uS/cm, 0.01 mS/cm, 1 ppm |
| 7 | ![]() |
Salinity/EC/TDS sensor | LMS-SAL104 | Conductivity: 0.1–500 mS/cm; TDS: 0–60000 ppm; Salinity: 0–500.00 ppt | ±1.5% FS | 1 uS/cm, 0.01 mS/cm, 1 ppm, 0.01 ppt |
| 8 | ![]() |
COD sensor | LMS-COD100 | COD: 0.1–1500 mg/L; TOC: 0.1–750 mg/L; BOD: 0.1–900 mg/L; Turbidity: 0.1–4000 NTU; Temp: 0–50℃ | ±5% equiv. KHP; Temp: ±0.5℃ | 0.01 mg/L equiv. KHP |
| 9 | ![]() |
TSS sensor | LMS-TSS100 | 0–50000 mg/L / 0–120000 mg/L | ±10% FS or 10 mg/L | 0.1 mg/L or 1 mg/L |
| 10 | ![]() |
Turbidity sensor | LMS-TUR10L | 0–100 NTU | ±10% FS or 0.3 NTU | 0.01 NTU |
| 11 | ![]() |
Turbidity sensor | LMS-TUR10H | 0–3000 NTU | ±10% FS or 0.3 NTU | 0.01 NTU |
| 12 | ![]() |
CO2 sensor | LMS-CO2100 | 2000 PPM / 10000 PPM / 50000 PPM | ±5% FS | 1 ppm |
| 13 | ![]() |
Ammonia Nitrogen sensor | LMS-NH4100 | 0–1000 mg/L | ±5% FS | — |
| 14 | ![]() |
Ion Selective sensor | LMS-ION100 | 0–1000 mg/L | ±5% FS | — |
| 15 | ![]() |
Oil in Water sensor | LMS-OIL100 | 0–50 mg/L; 0–5 mg/L | ±3% FS | 0.01 ppm |
| 16 | ![]() |
Chlorophyll sensor | LMS-CHL100 | 0–500 ug/L | ±3% FS | 0.1 ug/L |
| 17 | ![]() |
Blue-Green Algae sensor | LMS-BGA100 | 0–2,000,000 cells/ml | ±3% FS | — |
| 18 | ![]() |
Residual Chlorine sensor | LMS-HCLO100 | 0–20.00 ppm | ±5% FS | 0.001 / 0.01 ppm |
| 19 | ![]() |
Marine Current sensor | LMS-Current100 | Temp: -3℃–45℃; Velocity: 0–500 cm/s; Direction: 0–359.9° | ±0.05℃; ±1 cm/s or ±2%; ±2° | Temp: 0.001℃; Velocity: 0.1 cm/s; Direction: 0.1° |
| Water Quality Analyzer Equipment | ||||||
| No. | Picture | Product Name | Model | Size | Power | Display Output |
| 20 | ![]() |
Portable DO Analyzer | LMS-PA100 | 100mm × 204mm | <0.5 W; Power supply 7.5V, 5 batteries | LCD display screen |
| 21 | ![]() |
Multi-parameter Portable Water Analyzer | LMS-PA100P | 220mm × 120mm × 100mm | Rechargeable lithium battery with 220V to DC charging adapter | LCD display screen |
| 22 | ![]() |
Multi-parameter Touch-screen Online Analyzer | LMS-OA200T | 180mm × 230mm × 100mm | AC power supply: 220 VAC | 7-inch touch screen |
Frequently Asked Questions
Q What is the difference between DO Sensor Type B and Type C?
Type B is designed for online monitoring of clean water quality with faster response time (<120s) and higher accuracy (±0.1–0.3 mg/L), with optional built-in or external temperature sensing. Type C is specially designed for aquaculture in harsh water bodies, featuring a bacteriostatic and scratch-resistant fluorescent film with strong anti-interference ability and built-in temperature sensing (±0.3 mg/L accuracy).
Q What communication protocol do these DO sensors support?
Both DO Sensor Type B and Type C support RS-485 communication with MODBUS protocol, making them easy to integrate with existing monitoring systems, PLCs, and data loggers.
Q What power supply is required for the DO sensors?
The sensors operate on a 9–24 VDC power supply. A 12 VDC supply is recommended for optimal and stable performance in both field and online deployment scenarios.
Q Are these sensors suitable for use in aquaculture environments?
Yes. The DO Sensor Type C is specifically designed for aquaculture online monitoring. Its fluorescent film offers bacteriostasis, scratch resistance, and excellent anti-interference ability, making it highly suitable for harsh and biologically active water bodies such as fish farms and shrimp ponds.
Q What other water quality parameters can be monitored alongside dissolved oxygen?
The product line includes a comprehensive range of Digital RS485 water quality sensors covering pH, ORP, EC/TDS, salinity, COD, turbidity, TSS, CO2, ammonia nitrogen, residual chlorine, chlorophyll, blue-green algae, oil-in-water, and marine current — all compatible with MODBUS protocol for multi-parameter monitoring systems.
Q What analyzer options are available to display and manage sensor data?
Three analyzer options are available: the Portable DO Analyzer (LMS-PA100) with LCD display and battery power, the Multi-parameter Portable Water Analyzer (LMS-PA100P) with rechargeable lithium battery, and the Multi-parameter Touch-screen Online Analyzer (LMS-OA200T) featuring a 7-inch touch screen and AC 220V power supply for continuous online monitoring.



































