The COD Sensor is a cutting-edge digital water quality analyzer that leverages advanced ultraviolet absorption technology for accurate measurements of COD, TOC, BOD, turbidity, and temperature. Manufactured in China, this high-performance sensor is designed for seamless integration into automation systems, featuring RS-485 output and Modbus protocol. As a leading product from top suppliers in the industry, it boasts a self-cleaning brush and reagent-free operation, significantly reducing maintenance needs and environmental impact. With rapid response times of just seconds and automatic turbidity compensation, this reliable sensor is ideal for challenging industrial and environmental applications such as wastewater treatment, aquaculture, and environmental monitoring. Choose our factory-produced COD Sensor for exceptional quality and performance in your water quality analysis needs

    Product Parameters
    Product Name COD Sensor
    Measurement Method Ultraviolet Absorption Method
    Range COD: 0.1 ~ 1500 mg/L  |  0.1 ~ 500 mg/L
    TOC: 0.1 ~ 750 mg/L
    BOD: 0.1 ~ 900 mg/L
    Turbidity: 0.1 ~ 4000 NTU
    Temperature: 0 to 50 ℃
    Accuracy <5% equiv. KHP
    Temperature: ±0.5 ℃
    Power 9–24 VDC (Recommended: 12 VDC)
    Material 316L Stainless Steel
    Size 32 mm × 200 mm
    IP Protection IP68
    Output RS-485, MODBUS Protocol
    Product Features
    🔬
    1. Advanced Multi-Parameter Detection

    Simultaneously measures COD, TOC, BOD, turbidity, and temperature with a single sensor, reducing equipment costs and complexity.

    🛡️
    2. Robust Anti-Interference Design

    Automatic turbidity compensation eliminates measurement errors caused by suspended particles, ensuring high accuracy even in turbid water.

    ⚙️
    3. Maintenance-Free Operation

    Integrated self-cleaning brush prevents biofouling and extends maintenance cycles to over 12 months. Reagent-free design avoids chemical pollution and reduces operational costs.

    4. Rapid Response & High Stability

    Achieves results within tens of seconds with ±5% accuracy. Built-in temperature compensation ensures reliability across 0–50°C environments.

    🏭
    5. Industrial-Grade Durability

    316L stainless steel housing and IP68 rating withstand corrosion, high pressure, and harsh aquatic conditions.

    🔗
    6. Seamless Integration

    Supports RS-485 communication and Modbus protocol for easy connection to IoT platforms.

    Application
    🏗️
    1. Wastewater Treatment Plants

    Ideal for monitoring COD and BOD levels in industrial and municipal wastewater to ensure compliance with discharge regulations. The sensor's turbidity and temperature measurements also aid in optimizing treatment processes, such as adjusting aeration or chemical dosing, to improve efficiency and reduce operational costs.

    🌿
    2. Environmental Monitoring

    Used in rivers, lakes, and groundwater sites to track organic pollution trends. The reagent-free design makes it environmentally safe for long-term ecological studies, while multi-parameter capabilities provide a holistic view of water quality changes over time.

    🏭
    3. Industrial Process Control

    In manufacturing sectors like food and beverage, pharmaceuticals, and electronics, the sensor monitors process water quality in real time, preventing contamination and ensuring product consistency. Its resistance to harsh chemicals and high-temperature environments makes it a reliable choice for industrial pipelines and cooling systems.

    🐟
    4. Aquaculture and Agriculture

    Helps maintain optimal water conditions for fish farms by measuring dissolved organic matter (COD/BOD) and turbidity, which impact aquatic life health. In irrigation systems, it monitors nutrient levels and contaminants in source water, supporting sustainable agricultural practices.

    application
    Digital RS485 Water Quality Sensors Technical Data
    Parameter Model Range Accuracy
    DO Sensor LMS-DO10B 0–20 mg/L, 0–60 ℃ ±0.1–0.3 mg/L
    DO Sensor LMS-DO10C 0–20 mg/L, 0–60 ℃ ±0.3 mg/L
    Trace DO Sensor LMS-TDO100 0–2000 ppb, 0–50 ℃ ±1 ppb
    PH Sensor LMS-PH100 0–14 pH ±0.02 pH
    ORP Sensor LMS-ORP100 ±1000.0 mV ±0.2 mV
    EC/TDS Sensor LMS-TDS102 CT: 0–9999 uS/cm; 0–100 mS/cm
    TDS: 0–10000 ppm
    ±2.5% FS
    Salinity/EC/TDS Sensor LMS-SAL104 Conductivity: 0.1–500 mS/cm
    TDS: 0–60000 ppm
    Salinity: 0–500.00 ppt
    ±1.5% FS
    COD Sensor LMS-COD100 COD: 0.1–1500 mg/L
    TOC: 0.1–750 mg/L
    BOD: 0.1–900 mg/L
    Turbidity: 0.1–4000 NTU
    Temperature: 0–50 ℃
    ±5% equiv. KHP
    Temperature: ±0.5 ℃
    TSS Sensor LMS-TSS100 0–50000 mg/L / 0–120000 mg/L ±10% FS or 10 mg/L
    Turbidity Sensor LMS-TUR10L 0–100 NTU ±10% FS or 0.3 NTU
    Turbidity Sensor LMS-TUR10H 0–3000 NTU ±10% FS or 0.3 NTU
    CO₂ Sensor LMS-CO2100 2000 PPM / 10000 PPM / 50000 PPM ±5% FS
    Ammonia Nitrogen Sensor LMS-NH4100 0–1000 mg/L ±5% FS
    Ion Selective Sensor LMS-ION100 0–1000 mg/L ±5% FS
    Oil in Water Sensor LMS-OIL100 0–50 mg/L; 0–5 mg/L ±3% FS
    Chlorophyll Sensor LMS-CHL100 0–500 ug/L ±3% FS
    Blue-Green Algae Sensor LMS-BGA100 0–2,000,000 cells/ml ±3% FS
    Residual Chlorine Sensor LMS-HCLO100 0–20.00 ppm ±5% FS
    Marine Current Sensor LMS-Current100 Temperature: -3 ℃ – 45 ℃
    Velocity: 0–500 cm/s
    Flow Direction: 0–359.9°
    ±0.05 ℃
    ±1 cm/s or ±2%
    ±2°
    more products
    Frequently Asked Questions (FAQ)
    💬 What parameters can the COD Sensor (LMS-COD100) measure simultaneously?
    The LMS-COD100 COD Sensor can simultaneously measure five parameters: COD (Chemical Oxygen Demand), TOC (Total Organic Carbon), BOD (Biochemical Oxygen Demand), turbidity, and water temperature — all with a single probe.
    💬 How often does the COD sensor require maintenance?
    Thanks to its integrated self-cleaning brush that prevents biofouling, the COD sensor extends maintenance cycles to over 12 months under normal operating conditions. Its reagent-free design further reduces the need for routine servicing.
    💬 Is the COD sensor suitable for outdoor and submerged deployments?
    Yes. The sensor features an IP68 waterproof rating and is constructed from 316L stainless steel, making it fully suitable for long-term submerged deployment in rivers, lakes, wastewater treatment tanks, and other harsh aquatic environments.
    💬 What communication protocol does the sensor support for system integration?
    The COD sensor supports RS-485 communication with Modbus RTU protocol, enabling seamless integration with PLCs, data loggers, SCADA systems, and IoT monitoring platforms.
    💬 How does the sensor handle turbidity interference in COD measurements?
    The sensor incorporates an automatic turbidity compensation algorithm that actively corrects for measurement errors caused by suspended particles in the water. This ensures accurate COD and BOD readings even in highly turbid water conditions.
    💬 What is the power supply requirement for the COD sensor?
    The COD sensor operates on a 9–24 VDC power supply. A 12 VDC input is recommended for optimal and stable performance in field deployments.