China Suppliers Factory Aquaculture Fluorescence Dissolved Oxygen Meter DO Sensor Probe for Accurate Water Quality Monitoring

The LuminSens DO Sensor Type B is a cutting-edge solution for reliable online dissolved oxygen (DO) monitoring in clean water environments. This sensor, manufactured in China, utilizes advanced fluorescence lifetime technology, which eliminates issues related to oxygen consumption, flow rate restrictions, and maintenance requirements. With a fast response time of less than 120 seconds and exceptional accuracy of ±0.1-0.3 mg/L, it guarantees stable performance across various applications, including drinking water sources, municipal treatment facilities, and industrial processes. As a leading product from top suppliers and factories, the sensor features flexible temperature integration through built-in or external options and boasts a robust design, making it an ideal choice for continuous water quality assurance in controlled settings

    Product Parameters
    Product Name DO sensor type B
    Product Description Suitable for online monitoring of clean water quality. Temperature built-in or external.
    Respond Time < 120s
    Accuracy ±0.1-0.3mg/L
    Range 0~50℃、0~20mg⁄L
    Temperature Accuracy <0.3℃
    Working Temperature 0~40℃
    Storage Temperature -5~70℃
    Size φ32mm*170mm
    Power 9-24VDC(Recommend 12 VDC)
    Material Polymer Plastic
    Output RS-485, MODBUS protocol
    Product Features
    🔬
    ① Advanced Technology: Utilizes fluorescence lifetime technology for accurate, stable, and rapid dissolved oxygen measurement, overcoming limitations of traditional methods.
    ② Fast Response: Response time <120s, ensuring timely data acquisition for various applications.
    ③ Reliable Performance: High accuracy 0.1-0.3mg/L and stable operation within working temperature range of 0-40°C.
    🔌
    ④ Easy Integration: Supports RS-485 and MODBUS protocol for seamless connectivity, with power supply of 9-24VDC (recommended 12VDC).
    Application
    🧪
    Handheld Detection: Ideal for on-site water quality assessment in environmental monitoring, research, and quick field surveys, where portability and fast response are crucial.
    💧
    Online Water Quality Monitoring: Suitable for continuous monitoring in clean water environments such as drinking water sources, municipal water treatment plants, and industrial process water, ensuring water quality safety.
    🐟
    Aquaculture: Specifically designed for harsh aquaculture water bodies, helping monitor dissolved oxygen levels to maintain optimal aquatic health, prevent fish suffocation, and improve aquaculture efficiency.
    application
    Digital RS485 Water Quality Sensors Technical Data
    Digital RS485 Water Quality Sensors Technical Data
    No. Picture Product Name Model Range Accuracy Resolution
    1 Digital RS4851 DO sensor LMS-DO10B 0-20mg/L, 0-60℃ ±0.1-0.3mg/L 0.01mg/L
    2 Digital RS4852 DO sensor LMS-DO10C 0-20mg/L, 0-60℃ ±0.3mg/L 0.01mg/l
    3 Digital RS4853 Trace DO sensor LMS-TDO100 0-2000ppb, 0-50℃ ±1ppb 1ppb
    4 Digital RS4854 PH sensor LMS-PH100 0-14pH ±0.02pH 0.01pH
    5 Digital RS4854 ORP sensor LMS-ORP100 ±1000.0 mV ±0.2 mV 0.1mV
    6 Digital RS4856 EC/TDS sensor LMS-TDS102 CT: 0-9999uS/cm; 0-100mS/cm; TDS: 0-10000ppm ±2.5%FS 1uS/cm, 0.01mS/cm, 1ppm
    7 Digital RS4857 Salinity/EC/TDS sensor LMS-SAL104 Conductivity: 0.1-500 mS/cm; TDS: 0-60000ppm; Salinity: 0-500.00ppt ±1.5%FS 1uS/cm, 0.01mS/cm, 1ppm, 0.01ppt
    8 Digital RS4858 COD sensor LMS-COD100 COD: 0.1-1500mg/L; TOC: 0.1-750mg/L; BOD: 0.1-900mg/L; Turbidity: 0.1-4000NTU; Temp: 0-50℃ ±5% equiv.KHP; Temp: ±0.5℃ 0.01mg/L equiv.KHP
    9 Digital RS4859 TSS sensor LMS-TSS100 0-50000mg/L / 0-120000mg/L ±10%FS or 10 mg/L 0.1mg/L or 1mg/L
    10 Digital RS48510 Turbidity sensor LMS-TUR10L 0-100NTU ±10%FS or 0.3 NTU 0.01NTU
    11 Digital RS48510 Turbidity sensor LMS-TUR10H 0-3000NTU ±10%FS or 0.3 NTU 0.01NTU
    12 Digital RS48512 CO2 sensor LMS-CO2100 2000PPM / 10000PPM / 50000PPM ±5%FS 1ppm
    13 Digital RS48513 Ammonia Nitrogen sensor LMS-NH4100 0-1000 mg/L ±5%FS
    14 Digital RS48513 Ion Selective sensor LMS-ION100 0-1000 mg/L ±5%FS
    15 Digital RS48510 Oil in Water sensor LMS-OIL100 0-50 mg/L; 0-5 mg/L ±3%FS 0.01ppm
    16 Digital RS48510 Chlorophyll sensor LMS-CHL100 0-500ug/L ±3%FS 0.1ug/L
    17 Digital RS48510 Blue-Green Algae sensor LMS-BGA100 0-2,000,000 cells/ml ±3%FS
    18 Digital RS48518 Residual Chlorine sensor LMS-HCLO100 0 - 20.00 ppm ±5%FS 0.001 / 0.01ppm
    19 Digital RS48519 Marine Current sensor LMS-Current100 Temperature: -3℃ - 45℃; Velocity: 0-500 cm/s; Direction: 0-359.9° ±0.05℃; ±1 cm/s or ±2%; ±2° Temp: 0.001℃; Velocity: 0.1 cm/s; Direction: 0.1°
    Water Quality Analyzer Equipment
    No. Picture Product Name Model Size Power Display Output
    20 Digital RS48520 Portable DO Analyzer LMS-PA100 100mm*204mm <0.5W; Power supply 7.5V, 5 batteries LCD display screen
    21 Digital RS48521 Multi-parameter Portable Water Analyzer LMS-PA100P 220mm*120mm*100mm Rechargeable lithium battery with 220V to DC charging adapter LCD display screen
    22 Digital RS48522 Multi-parameter Touch-screen Online Analyzer LMS-OA200T 180mm×230mm×100mm AC power supply: 220 VAC 7-inch touch screen
    more products
    Frequently Asked Questions (FAQ)
    Q
    What technology does the DO sensor type B use to measure dissolved oxygen?
    The DO sensor type B utilizes fluorescence lifetime technology, which provides accurate, stable, and rapid dissolved oxygen measurement. This method overcomes the limitations of traditional electrochemical methods, such as oxygen consumption and membrane fouling.
    Q
    What is the response time and accuracy of the DO sensor type B?
    The DO sensor type B has a response time of less than 120 seconds and offers a high measurement accuracy of ±0.1–0.3 mg/L, making it suitable for precise water quality monitoring applications.
    Q
    What communication protocol does the DO sensor type B support?
    The sensor supports RS-485 communication with MODBUS protocol, enabling easy integration into existing monitoring systems, PLCs, and data loggers. The recommended power supply is 12VDC (9–24VDC range supported).
    Q
    What are the main application scenarios for this DO sensor?
    The DO sensor type B is suitable for three main scenarios: handheld field detection for environmental surveys, online continuous monitoring in drinking water and municipal treatment plants, and aquaculture monitoring to maintain optimal dissolved oxygen levels for aquatic life.
    Q
    What other water quality sensors are available in the RS485 digital sensor series?
    The RS485 digital water quality sensor series includes a wide range of sensors such as pH, ORP, EC/TDS, Salinity, COD, TSS, Turbidity, CO2, Ammonia Nitrogen, Ion Selective, Oil in Water, Chlorophyll, Blue-Green Algae, Residual Chlorine, and Marine Current sensors, all supporting MODBUS RS485 protocol.
    Q
    Are there compatible analyzer devices available for use with these sensors?
    Yes, compatible analyzer equipment is available, including the Portable DO Analyzer (LMS-PA100), Multi-parameter Portable Water Analyzer (LMS-PA100P) with rechargeable battery, and the Multi-parameter Touch-screen Online Analyzer (LMS-OA200T) with a 7-inch touch screen and 220VAC power supply.

    Leave Your Message

    AI Helps Write