China Suppliers Factory Multi-Parameter Water Quality Sensor for BOD, TOC, COD, Turbidity, and Temperature

,

Introducing the LMS-COD100 series water quality sensor, offered by leading China suppliers and manufactured in advanced facilities. This series, which includes models LMS-COD100H and LMS-COD100L, utilizes cutting-edge ultraviolet absorption technology to provide integrated monitoring of five essential water quality parameters: COD, TOC, BOD, turbidity, and temperature. Designed for seamless integration with automation and IoT monitoring systems, it features digital RS-485 output and supports the Modbus protocol.

,

Our reagent-free design not only eliminates chemical pollution but also significantly lowers operational costs. Equipped with a built-in self-cleaning brush, the LMS-COD100 effectively prevents biological adhesion, extending the maintenance cycle. This sensor boasts automatic turbidity interference compensation and chloride ion anti-interference capabilities, ensuring reliable performance. With a rapid response time (in seconds), low failure rate, and high stability, the LMS-COD100 series provides accurate and dependable data for various water quality monitoring applications.

,

    Product Parameters
    Product Name COD Sensor
    Model LMS-COD100H LMS-COD100L
    Range

    COD: 0.1~1500mg/L ; 0.1~500mg/L

    TOC: 0.1~750mg/L

    BOD: 0.1~900mg/L

    Turbidity: 0.1 ~ 4000 NTU

    Temperature range: 0 to 50℃

    COD: 0.1~500mg/L

    TOC: 0.1~200mg/L

    BOD: 0.1~300mg/L

    Turbidity: 0.1 ~ 1000 NTU

    Temperature range: 0 to 50℃

    Measurement Method Ultraviolet absorption method
    Accuracy <5% equiv.KHP
    Temperature: ±0.5℃
    Power 9-24VDC (Recommend 12 VDC)
    Material 316L Stainless Steel
    Size 32mm * 200mm
    IP Protection IP68
    Output RS-485, MODBUS Protocol
    Certificate CE, ISO9001
    Product Features
    1 Dual-Model Multi-Parameter Detection
    Equipped with LMS-COD100H and LMS-COD100L two models to meet different range monitoring needs, a single sensor can simultaneously measure COD, TOC, BOD, turbidity and temperature, reducing the number of equipment deployment and the complexity of the monitoring system.
    2 Reagent-Free & Environmentally Friendly
    The whole detection process does not need to add any chemical reagents, which not only eliminates the risk of secondary pollution to the water body, but also saves the long-term reagent purchase cost, and is more in line with the environmental protection requirements of ecological monitoring.
    1-3
    2-3
    3 Intelligent Anti-Interference & High Precision
    It has automatic turbidity interference compensation function, which can eliminate the measurement error caused by suspended particles in water; at the same time, it is not affected by chloride ions, ensuring that the detection data is accurate and stable, with the accuracy of COD and other parameters less than 5% equiv.KHP.
    4 Self-Cleaning & Low Maintenance
    The integrated self-cleaning brush can automatically remove the biological attachments on the sensor surface, effectively extending the maintenance cycle, and the equipment has the characteristics of low failure rate, reducing the later operation and maintenance workload of users.
    4-3
    7-3
    5 Fast Response & Easy Integration
    The sensor can output detection results within tens of seconds, realizing real-time monitoring of water quality; it supports RS-485 digital output and Modbus protocol, which can be quickly connected to various industrial control systems and IoT platforms, with simple operation and strong compatibility.
    6-3
    5-3
    Application
    A Municipal & Industrial Wastewater Treatment
    For municipal sewage treatment plants and industrial wastewater discharge points, the dual-model sensor can be selected according to the pollution degree of water body. It can monitor COD, BOD and other key indicators in real time to ensure that the effluent meets the discharge standards, and the turbidity and temperature data can also assist in optimizing the treatment process and reducing energy consumption.
    B Ecological Water Body Monitoring
    In rivers, lakes and reservoirs, the reagent-free design of the sensor avoids damaging the ecological environment of the water body, and the multi-parameter detection can comprehensively reflect the organic pollution and turbidity changes of the water body, providing a basis for water ecological restoration and protection.
    C Aquaculture Water Quality Management
    In fish and shrimp breeding ponds, the sensor can monitor the content of organic matter (COD/BOD) and turbidity of the water body in real time. When the index exceeds the standard, it can give an early warning in time, helping farmers adjust the water quality in time and maintain the healthy growth environment of aquatic products.
    D Process Water Monitoring in Food & Pharmaceutical Industry
    In food processing, pharmaceutical production and other fields, the sensor can monitor the quality of process water to prevent organic pollution from affecting product quality, and its high stability and anti-interference performance can adapt to the complex water quality environment in the production workshop.
    application
    More Products
    Digital RS485 Water Quality Sensors Technical Data
    No. Picture Product Name Model Range Accuracy Resolution
    1 Digital RS4851 DO sensor LMS-DO10B 0-20mg/L, 0-60℃ ±0.1-0.3mg/L 0.01mg/L
    2 Digital RS4852 DO sensor LMS-DO10C 0-20mg/L, 0-60℃ ±0.3mg/L 0.01mg/l
    3 Digital RS4853 Trace DO sensor LMS-TDO100 0-2000ppb, 0-50℃ ±1ppb 1ppb
    4 Digital RS4854 PH sensor LMS-PH100 0-14pH ±0.02pH 0.01pH
    5 Digital RS4854 ORP sensor LMS-ORP100 ±1000.0 mV ±0.2 mV 0.1mV
    6 Digital RS4856 EC/TDS sensor LMS-TDS102 CT: 0-9999uS/cm; 0-100mS/cm;
    TDS: 0-10000ppm
    ±2.5%FS 1uS/cm, 0.01mS/cm
    1ppm
    7 Digital RS4857 Salinity/EC/TDS sensor LMS-SAL104 Conductivity: 0.1-500 mS/cm
    TDS: 0-60000ppm
    Salinity: 0-500.00ppt
    ±1.5%FS 1uS/cm, 0.01mS/cm
    1ppm, 0.01ppt
    8 Digital RS4858 COD sensor LMS-COD100 COD: 0.1-1500mg/L
    TOC: 0.1-750mg/L
    BOD: 0.1-900mg/L
    Turbidity: 0.1-4000NTU
    Temperature range: 0-50 ℃
    ±5% equiv.KHP
    Temperature: ± 0.5 ℃
    0.01mg/L equiv.KHP
    9 Digital RS4859 TSS sensor LMS-TSS100 0-50000mg/L / 0-120000mg/L ±10%FS or 10 mg/L 0.1mg/L or 1mg/L
    10 Digital RS48510 Turbidity sensor LMS-TUR10L 0-100NTU ±10%FS or 0.3 NTU 0.01NTU
    11 Digital RS48510 Turbidity sensor LMS-TUR10H 0-3000NTU ±10%FS or 0.3 NTU 0.01NTU
    12 Digital RS48512 CO2 sensor LMS-CO2100 2000PPM / 10000PPM / 50000PPM ±5%FS 1ppm
    13 Digital RS48513 Ammonia Nitrogen sensor LMS-NH4100 0-1000 mg/L ±5%FS
    14 Digital RS48513 Ion Selective sensor LMS-ION100 0-1000 mg/L ±5%FS
    15 Digital RS48510 Oil in Water sensor LMS-OIL100 0-50 mg/L ; 0-5 mg/L ±3%FS 0.01ppm
    16 Digital RS48510 Chlorophyll sensor LMS-CHL100 0-500ug/L ±3%FS 0.1ug/L
    17 Digital RS48510 Blue-Green Algae sensor LMS-BGA100 0-2000,000 cells/ml ±3%FS
    18 Digital RS48518 Residual Chlorine sensor LMS-HCLO100 0 - 20.00 ppm ±5%FS 0.001 / 0.01ppm
    19 Digital RS48519 Marine Current sensor LMS-Current100 Temperature: -3℃ - 45℃
    Velocity of flow: 0-500 cm/s
    Flow direction: 0-359.9°
    ±0.05℃
    ±1 cm/s or ±2%
    ±2°
    Temperature: 0.001℃
    Velocity of flow: 0.1 cm/s
    Flow direction: 0.1°
    Water Quality Analyzer Equipment
    No. Picture Product Name Model Size Power Display Output
    20 Digital RS48520 Protable DO Analyzer LMS-PA100 100mm*204mm < 0.5 W Power supply 7.5V, 5 batteries LCD display screen
    21 Digital RS48521 Multi-parameter Protable Water Analyzer LMS-PA100P 220mm*120mm*100mm Rechargeable lithium battery with 220v to dc charging adapter LCD display screen
    22 Digital RS48522 Multi-parameter Touch-screen Online Analyzer LMS-OA200T 180mmx230mmx100mm AC power supply: 220 VAC 7-inch touch screen
    Frequently Asked Questions
    What parameters can the LMS-COD series sensor measure simultaneously?
    The LMS-COD series sensor is designed for multi-parameter detection. It can simultaneously measure Chemical Oxygen Demand (COD), Total Organic Carbon (TOC), Biochemical Oxygen Demand (BOD), Turbidity, and Temperature using a single integrated probe.
    How does the sensor perform measurements without chemical reagents?
    The sensor utilizes the ultraviolet (UV) absorption method. It measures the absorption of UV light by organic matter in the water at specific wavelengths. This physical measurement process is reagent-free, environmentally friendly, and eliminates secondary chemical pollution.
    What is the difference between LMS-COD100H and LMS-COD100L?
    The key difference lies in their measurement ranges. LMS-COD100H is designed for higher concentration applications, supporting COD ranges up to 1500mg/L and Turbidity up to 4000 NTU. LMS-COD100L is optimized for lower concentration monitoring with highly sensitive ranges up to 500mg/L COD and 1000 NTU Turbidity.
    Does the sensor require frequent manual cleaning?
    No, the sensor features an integrated automatic self-cleaning brush. This built-in system automatically sweeps away biological attachments and suspended solids from the optical window, significantly reducing maintenance frequency and ensuring long-term accuracy.
    How does the sensor manage turbidity interference?
    The sensor is equipped with an intelligent automatic turbidity compensation function. It utilizes a secondary optical measurement path to detect suspended solids and calculate compensation algorithms, ensuring stable and reliable COD readings even in highly turbid water.
    What industrial outputs and protocols does the sensor support?
    The sensor supports standard RS-485 digital output and uses the Modbus RTU communication protocol. This allows seamless integration with PLC systems, SCADA, industrial controllers, and various IoT platforms.