This Total Suspended Solids (TSS) Analyzer, designed to meet the ISO7027 international standard, employs advanced 135° backlight scattering technology to deliver accurate measurements for various applications, including industrial wastewater analysis, environmental water monitoring, and process control systems. Manufactured by a leading factory in China, this high-quality sensor is built to withstand harsh environments, featuring a durable 316L stainless steel housing that is both corrosion-resistant and equipped with sunlight-resistant optics

    Product Parameters
    Product Name Total Suspended Solid Analyzer (TSS Analyzer)
    Measurement Method 135° Backlight
    Range 0–50,000 mg/L  |  0–120,000 mg/L
    Accuracy Less than ±10% of measured value (depending on sludge homogeneity) or 10 mg/L, whichever is greater
    Power 9–24 VDC (Recommended: 12 VDC)
    Size 50 mm × 200 mm
    Material 316L Stainless Steel
    Output RS-485, MODBUS Protocol
    Product Features
    ISO7027-Compliant Precision

    Advanced optics and 135° scattering angle ensure globally standardized measurements for TSS and turbidity, validated across diverse water matrices.

    Robust Anti-Interference Design

    Proprietary fiber-optic pathways and dynamic signal correction algorithms minimize errors from ambient light, temperature fluctuations, or chromatic variations.

    Automated Maintenance System

    Motor-driven cleaning brush operates at programmable intervals, preventing biofilm buildup and ensuring zero downtime in continuous monitoring scenarios.

    Compact & Industrial-Grade Durability

    The 316L stainless steel body withstands corrosive chemicals, high-pressure washdowns, and extreme temperatures (-20°C to 60°C), suitable for submerged or outdoor installations.

    Multi-Parameter Compensation

    Built-in temperature and turbidity compensation algorithms enhance accuracy in dynamic environments, from rapid sediment flows to stagnant wastewater.

    Application
    🏭
    1. Industrial Effluent Management

    Optimize sludge dewatering and discharge compliance by tracking TSS in real time across chemical, pharmaceutical, or textile wastewater streams.

    🌿
    2. Environmental Protection

    Deploy in rivers, lakes, or coastal zones to monitor erosion, sediment transport, and pollution events for regulatory reporting.

    🚰
    3. Municipal Water Systems

    Ensure drinking water safety by detecting suspended particles in treatment plants or distribution networks, preventing pipeline blockages.

    🐟
    4. Aquaculture & Fisheries

    Maintain aquatic health by controlling suspended solids that impact oxygen levels and species survival rates.

    ⛏️
    5. Mining & Construction

    Monitor runoff water quality to mitigate environmental risks and comply with particulate emission standards.

    🔬
    6. Research & Labs

    Support studies on water clarity, sediment dynamics, or ecological impact assessments with lab-grade precision.

    application
    More Products
    Digital RS485 Water Quality Sensors Technical Data
    No. Picture Product Name Model Range Accuracy Resolution
    1 Digital RS4851 DO sensor LMS-DO10B 0-20mg/L, 0-60℃ ±0.1-0.3mg/L 0.01mg/L
    2 Digital RS4852 DO sensor LMS-DO10C 0-20mg/L, 0-60℃ ±0.3mg/L 0.01mg/l
    3 Digital RS4853 Trace DO sensor LMS-TDO100 0-2000ppb, 0-50℃ ±1ppb 1ppb
    4 Digital RS4854 PH sensor LMS-PH100 0-14pH ±0.02pH 0.01pH
    5 Digital RS4854 ORP sensor LMS-ORP100 ±1000.0 mV ±0.2 mV 0.1mV
    6 Digital RS4856 EC/TDS sensor LMS-TDS102 CT: 0-9999uS/cm; 0-100mS/cm; TDS: 0-10000ppm ±2.5%FS 1uS/cm, 0.01mS/cm, 1ppm
    7 Digital RS4857 Salinity/EC/TDS sensor LMS-SAL104 Conductivity: 0.1-500 mS/cm; TDS: 0-60000ppm; Salinity: 0-500.00ppt ±1.5%FS 1uS/cm, 0.01mS/cm, 1ppm, 0.01ppt
    8 Digital RS4858 COD sensor LMS-COD100 COD: 0.1-1500mg/L; TOC: 0.1-750mg/L; BOD: 0.1-900mg/L; Turbidity: 0.1-4000NTU; Temp: 0-50℃ ±5% equiv.KHP; Temp: ±0.5℃ 0.01mg/L equiv.KHP
    9 Digital RS4859 TSS sensor LMS-TSS100 0-50000mg/L / 0-120000mg/L ±10%FS or 10 mg/L 0.1mg/L or 1mg/L
    10 Digital RS48510 Turbidity sensor LMS-TUR10L 0-100NTU ±10%FS or 0.3 NTU 0.01NTU
    11 Digital RS48510 Turbidity sensor LMS-TUR10H 0-3000NTU ±10%FS or 0.3 NTU 0.01NTU
    12 Digital RS48512 CO2 sensor LMS-CO2100 2000PPM / 10000PPM / 50000PPM ±5%FS 1ppm
    13 Digital RS48513 Ammonia Nitrogen sensor LMS-NH4100 0-1000 mg/L ±5%FS
    14 Digital RS48513 Ion Selective sensor LMS-ION100 0-1000 mg/L ±5%FS
    15 Digital RS48510 Oil in Water sensor LMS-OIL100 0-50 mg/L; 0-5 mg/L ±3%FS 0.01ppm
    16 Digital RS48510 Chlorophyll sensor LMS-CHL100 0-500ug/L ±3%FS 0.1ug/L
    17 Digital RS48510 Blue-Green Algae sensor LMS-BGA100 0-2,000,000 cells/ml ±3%FS
    18 Digital RS48518 Residual Chlorine sensor LMS-HCLO100 0-20.00 ppm ±5%FS 0.001 / 0.01ppm
    19 Digital RS48519 Marine Current sensor LMS-Current100 Temp: -3℃–45℃; Velocity: 0-500 cm/s; Direction: 0-359.9° ±0.05℃; ±1 cm/s or ±2%; ±2° Temp: 0.001℃; Velocity: 0.1 cm/s; Direction: 0.1°
    Water Quality Analyzer Equipment
    No. Picture Product Name Model Size Power Display Output
    20 Digital RS48520 Portable DO Analyzer LMS-PA100 100mm × 204mm <0.5W; 7.5V, 5 batteries LCD display screen
    21 Digital RS48521 Multi-parameter Portable Water Analyzer LMS-PA100P 220mm × 120mm × 100mm Rechargeable lithium battery with 220V DC charging adapter LCD display screen
    22 Digital RS48522 Multi-parameter Touch-screen Online Analyzer LMS-OA200T 180mm × 230mm × 100mm AC power supply: 220 VAC 7-inch touch screen
    more products
    Frequently Asked Questions (FAQ)
    Q What is the measurement principle of the TSS Analyzer?
    The TSS Analyzer uses a 135° backscatter optical method. An infrared light beam is projected into the water sample, and the sensor measures the intensity of light scattered back at a 135° angle by suspended particles. This method complies with ISO 7027 standards and provides accurate, reliable TSS measurements across a wide concentration range.
    Q What is the measurement range of the LMS-TSS100 sensor?
    The LMS-TSS100 TSS sensor supports two measurement ranges: 0–50,000 mg/L for standard wastewater and sludge applications, and 0–120,000 mg/L for high-concentration environments such as industrial effluents or mining runoff. The appropriate range can be selected based on the application requirements.
    Q How does the self-cleaning mechanism work, and how often does it activate?
    The sensor is equipped with a motor-driven mechanical cleaning brush that automatically wipes the optical window at user-programmable intervals. This prevents fouling, biofilm accumulation, and sediment buildup on the optical surface, ensuring continuous, maintenance-free operation in demanding environments such as activated sludge tanks or industrial discharge points.
    Q What communication protocol does the TSS Analyzer support?
    The TSS Analyzer outputs data via RS-485 using the MODBUS RTU protocol. This industry-standard interface allows seamless integration with PLCs, SCADA systems, data loggers, and multi-parameter online water quality analyzers such as the LMS-OA200T, enabling real-time remote monitoring and data logging.
    Q Is the TSS sensor suitable for outdoor or submerged installation?
    Yes. The sensor body is constructed from 316L stainless steel, which offers excellent resistance to corrosion, chemical exposure, and mechanical stress. It is designed to operate in temperatures ranging from -20°C to 60°C, making it suitable for submerged deployment in rivers, wastewater tanks, or outdoor environmental monitoring stations.
    Q Can the TSS Analyzer be used alongside other water quality sensors?
    Absolutely. The TSS Analyzer is part of a comprehensive range of RS-485 digital water quality sensors that includes DO, pH, ORP, COD, turbidity, EC/TDS, ammonia nitrogen, residual chlorine, and more. All sensors share compatible communication protocols and can be connected to the same multi-parameter online analyzer or data acquisition system for simultaneous multi-parameter monitoring.