China TSS Analyzer - Portable Total Suspended Solid Sensor for Sewage Treatment from Trusted Suppliers and Factory
| Product Name | Total Suspended Solid Analyzer (TSS Analyzer) |
| Measurement Method | 135° Backlight |
| Range | 0–50,000 mg/L | 0–120,000 mg/L |
| Accuracy | Less than ±10% of measured value (depending on sludge homogeneity) or 10 mg/L, whichever is greater |
| Power | 9–24 VDC (Recommend 12 VDC) |
| Size | 50 mm × 200 mm |
| Material | 316L Stainless Steel |
| Output | RS-485, MODBUS Protocol |
Advanced optics and 135° scattering angle ensure globally standardized measurements for TSS and turbidity, validated across diverse water matrices.
Proprietary fiber-optic pathways and dynamic signal correction algorithms minimize errors from ambient light, temperature fluctuations, or chromatic variations.
Motor-driven cleaning brush operates at programmable intervals, preventing biofilm buildup and ensuring zero downtime in continuous monitoring scenarios.
The 316L stainless steel body withstands corrosive chemicals, high-pressure washdowns, and extreme temperatures (-20°C to 60°C), suitable for submerged or outdoor installations.
Built-in temperature and turbidity compensation algorithms enhance accuracy in dynamic environments, from rapid sediment flows to stagnant wastewater.
Optimize sludge dewatering and discharge compliance by tracking TSS in real time across chemical, pharmaceutical, or textile wastewater streams.
Deploy in rivers, lakes, or coastal zones to monitor erosion, sediment transport, and pollution events for regulatory reporting.
Ensure drinking water safety by detecting suspended particles in treatment plants or distribution networks, preventing pipeline blockages.
Maintain aquatic health by controlling suspended solids that impact oxygen levels and species survival rates.
Monitor runoff water quality to mitigate environmental risks and comply with particulate emission standards.
Support studies on water clarity, sediment dynamics, or ecological impact assessments with lab-grade precision.
| Digital RS485 Water Quality Sensors Technical Data | ||||||
| No. | Picture | Product Name | Model | Range | Accuracy | Resolution |
| 1 | ![]() |
DO sensor | LMS-DO10B | 0–20 mg/L, 0–60℃ | ±0.1–0.3 mg/L | 0.01 mg/L |
| 2 | ![]() |
DO sensor | LMS-DO10C | 0–20 mg/L, 0–60℃ | ±0.3 mg/L | 0.01 mg/L |
| 3 | ![]() |
Trace DO sensor | LMS-TDO100 | 0–2000 ppb, 0–50℃ | ±1 ppb | 1 ppb |
| 4 | ![]() |
PH sensor | LMS-PH100 | 0–14 pH | ±0.02 pH | 0.01 pH |
| 5 | ![]() |
ORP sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV | 0.1 mV |
| 6 | ![]() |
EC/TDS sensor | LMS-TDS102 | CT: 0–9999 uS/cm; 0–100 mS/cm; TDS: 0–10000 ppm | ±2.5% FS | 1 uS/cm, 0.01 mS/cm, 1 ppm |
| 7 | ![]() |
Salinity/EC/TDS sensor | LMS-SAL104 | Conductivity: 0.1–500 mS/cm; TDS: 0–60000 ppm; Salinity: 0–500.00 ppt | ±1.5% FS | 1 uS/cm, 0.01 mS/cm, 1 ppm, 0.01 ppt |
| 8 | ![]() |
COD sensor | LMS-COD100 | COD: 0.1–1500 mg/L; TOC: 0.1–750 mg/L; BOD: 0.1–900 mg/L; Turbidity: 0.1–4000 NTU; Temp: 0–50℃ | ±5% equiv. KHP; Temp: ±0.5℃ | 0.01 mg/L equiv. KHP |
| 9 | ![]() |
TSS sensor | LMS-TSS100 | 0–50000 mg/L / 0–120000 mg/L | ±10% FS or 10 mg/L | 0.1 mg/L or 1 mg/L |
| 10 | ![]() |
Turbidity sensor | LMS-TUR10L | 0–100 NTU | ±10% FS or 0.3 NTU | 0.01 NTU |
| 11 | ![]() |
Turbidity sensor | LMS-TUR10H | 0–3000 NTU | ±10% FS or 0.3 NTU | 0.01 NTU |
| 12 | ![]() |
CO2 sensor | LMS-CO2100 | 2000 PPM / 10000 PPM / 50000 PPM | ±5% FS | 1 ppm |
| 13 | ![]() |
Ammonia Nitrogen sensor | LMS-NH4100 | 0–1000 mg/L | ±5% FS | — |
| 14 | ![]() |
Ion Selective sensor | LMS-ION100 | 0–1000 mg/L | ±5% FS | — |
| 15 | ![]() |
Oil in Water sensor | LMS-OIL100 | 0–50 mg/L; 0–5 mg/L | ±3% FS | 0.01 ppm |
| 16 | ![]() |
Chlorophyll sensor | LMS-CHL100 | 0–500 ug/L | ±3% FS | 0.1 ug/L |
| 17 | ![]() |
Blue-Green Algae sensor | LMS-BGA100 | 0–2,000,000 cells/ml | ±3% FS | — |
| 18 | ![]() |
Residual Chlorine sensor | LMS-HCLO100 | 0–20.00 ppm | ±5% FS | 0.001 / 0.01 ppm |
| 19 | ![]() |
Marine Current sensor | LMS-Current100 | Temperature: -3℃–45℃; Velocity: 0–500 cm/s; Direction: 0–359.9° | ±0.05℃; ±1 cm/s or ±2%; ±2° | Temp: 0.001℃; Velocity: 0.1 cm/s; Direction: 0.1° |
| Water Quality Analyzer Equipment | ||||||
| No. | Picture | Product Name | Model | Size | Power | Display Output |
| 20 | ![]() |
Portable DO Analyzer | LMS-PA100 | 100 mm × 204 mm | <0.5 W; 7.5V, 5 batteries | LCD Display Screen |
| 21 | ![]() |
Multi-parameter Portable Water Analyzer | LMS-PA100P | 220 mm × 120 mm × 100 mm | Rechargeable lithium battery with 220V DC charging adapter | LCD Display Screen |
| 22 | ![]() |
Multi-parameter Touch-screen Online Analyzer | LMS-OA200T | 180 mm × 230 mm × 100 mm | AC 220 VAC | 7-inch Touch Screen |