China TSS Analyzer - Portable Total Suspended Solid Sensor for Sewage Treatment from Trusted Suppliers and Factory

This Total Suspended Solids (TSS) Analyzer, manufactured by leading China suppliers, employs advanced 135° backlight scattering technology in accordance with the ISO7027 international standard. It ensures accurate measurements in various applications, including industrial wastewater treatment, environmental monitoring, and process control systems. Designed to withstand harsh conditions, the sensor features durable, corrosion-resistant 316L stainless steel housing and sunlight-resistant optics, guaranteeing reliable performance with minimal drift, The TSS Analyzer is equipped with an integrated automatic cleaning brush that effectively removes contamination and bubbles, enhancing measurement accuracy. Its compact design requires only 30mL of calibration liquid, ensuring a quick and straightforward setup. With an impressive measurement range of 0–120,000 mg/L and RS-485 MODBUS output, this device is optimal for environments with high turbidity or variable water conditions, making it an essential tool for factories and industries where precision is critical. Choose our TSS Analyzer to elevate your monitoring capabilities and achieve superior results in water quality assessment

    Product Parameters
    Product Name Total Suspended Solid Analyzer (TSS Analyzer)
    Measurement Method 135° Backlight
    Range 0–50,000 mg/L  |  0–120,000 mg/L
    Accuracy Less than ±10% of measured value (depending on sludge homogeneity) or 10 mg/L, whichever is greater
    Power 9–24 VDC (Recommend 12 VDC)
    Size 50 mm × 200 mm
    Material 316L Stainless Steel
    Output RS-485, MODBUS Protocol
    Product Features
    ① ISO7027-Compliant Precision

    Advanced optics and 135° scattering angle ensure globally standardized measurements for TSS and turbidity, validated across diverse water matrices.

    ② Robust Anti-Interference Design

    Proprietary fiber-optic pathways and dynamic signal correction algorithms minimize errors from ambient light, temperature fluctuations, or chromatic variations.

    ③ Automated Maintenance System

    Motor-driven cleaning brush operates at programmable intervals, preventing biofilm buildup and ensuring zero downtime in continuous monitoring scenarios.

    ④ Compact & Industrial-Grade Durability

    The 316L stainless steel body withstands corrosive chemicals, high-pressure washdowns, and extreme temperatures (-20°C to 60°C), suitable for submerged or outdoor installations.

    ⑤ Multi-Parameter Compensation

    Built-in temperature and turbidity compensation algorithms enhance accuracy in dynamic environments, from rapid sediment flows to stagnant wastewater.

    Application
    1. Industrial Effluent Management

    Optimize sludge dewatering and discharge compliance by tracking TSS in real time across chemical, pharmaceutical, or textile wastewater streams.

    2. Environmental Protection

    Deploy in rivers, lakes, or coastal zones to monitor erosion, sediment transport, and pollution events for regulatory reporting.

    3. Municipal Water Systems

    Ensure drinking water safety by detecting suspended particles in treatment plants or distribution networks, preventing pipeline blockages.

    4. Aquaculture & Fisheries

    Maintain aquatic health by controlling suspended solids that impact oxygen levels and species survival rates.

    5. Mining & Construction

    Monitor runoff water quality to mitigate environmental risks and comply with particulate emission standards.

    6. Research & Labs

    Support studies on water clarity, sediment dynamics, or ecological impact assessments with lab-grade precision.

    application
    More Products
    Digital RS485 Water Quality Sensors Technical Data
    No. Picture Product Name Model Range Accuracy Resolution
    1 DO sensor LMS-DO10B DO sensor LMS-DO10B 0–20 mg/L, 0–60℃ ±0.1–0.3 mg/L 0.01 mg/L
    2 DO sensor LMS-DO10C DO sensor LMS-DO10C 0–20 mg/L, 0–60℃ ±0.3 mg/L 0.01 mg/L
    3 Trace DO sensor LMS-TDO100 Trace DO sensor LMS-TDO100 0–2000 ppb, 0–50℃ ±1 ppb 1 ppb
    4 PH sensor LMS-PH100 PH sensor LMS-PH100 0–14 pH ±0.02 pH 0.01 pH
    5 ORP sensor LMS-ORP100 ORP sensor LMS-ORP100 ±1000.0 mV ±0.2 mV 0.1 mV
    6 EC/TDS sensor LMS-TDS102 EC/TDS sensor LMS-TDS102 CT: 0–9999 uS/cm; 0–100 mS/cm; TDS: 0–10000 ppm ±2.5% FS 1 uS/cm, 0.01 mS/cm, 1 ppm
    7 Salinity/EC/TDS sensor LMS-SAL104 Salinity/EC/TDS sensor LMS-SAL104 Conductivity: 0.1–500 mS/cm; TDS: 0–60000 ppm; Salinity: 0–500.00 ppt ±1.5% FS 1 uS/cm, 0.01 mS/cm, 1 ppm, 0.01 ppt
    8 COD sensor LMS-COD100 COD sensor LMS-COD100 COD: 0.1–1500 mg/L; TOC: 0.1–750 mg/L; BOD: 0.1–900 mg/L; Turbidity: 0.1–4000 NTU; Temp: 0–50℃ ±5% equiv. KHP; Temp: ±0.5℃ 0.01 mg/L equiv. KHP
    9 TSS sensor LMS-TSS100 TSS sensor LMS-TSS100 0–50000 mg/L / 0–120000 mg/L ±10% FS or 10 mg/L 0.1 mg/L or 1 mg/L
    10 Turbidity sensor LMS-TUR10L Turbidity sensor LMS-TUR10L 0–100 NTU ±10% FS or 0.3 NTU 0.01 NTU
    11 Turbidity sensor LMS-TUR10H Turbidity sensor LMS-TUR10H 0–3000 NTU ±10% FS or 0.3 NTU 0.01 NTU
    12 CO2 sensor LMS-CO2100 CO2 sensor LMS-CO2100 2000 PPM / 10000 PPM / 50000 PPM ±5% FS 1 ppm
    13 Ammonia Nitrogen sensor LMS-NH4100 Ammonia Nitrogen sensor LMS-NH4100 0–1000 mg/L ±5% FS
    14 Ion Selective sensor LMS-ION100 Ion Selective sensor LMS-ION100 0–1000 mg/L ±5% FS
    15 Oil in Water sensor LMS-OIL100 Oil in Water sensor LMS-OIL100 0–50 mg/L; 0–5 mg/L ±3% FS 0.01 ppm
    16 Chlorophyll sensor LMS-CHL100 Chlorophyll sensor LMS-CHL100 0–500 ug/L ±3% FS 0.1 ug/L
    17 Blue-Green Algae sensor LMS-BGA100 Blue-Green Algae sensor LMS-BGA100 0–2,000,000 cells/ml ±3% FS
    18 Residual Chlorine sensor LMS-HCLO100 Residual Chlorine sensor LMS-HCLO100 0–20.00 ppm ±5% FS 0.001 / 0.01 ppm
    19 Marine Current sensor LMS-Current100 Marine Current sensor LMS-Current100 Temperature: -3℃–45℃; Velocity: 0–500 cm/s; Direction: 0–359.9° ±0.05℃; ±1 cm/s or ±2%; ±2° Temp: 0.001℃; Velocity: 0.1 cm/s; Direction: 0.1°
    Water Quality Analyzer Equipment
    No. Picture Product Name Model Size Power Display Output
    20 Portable DO Analyzer LMS-PA100 Portable DO Analyzer LMS-PA100 100 mm × 204 mm <0.5 W; 7.5V, 5 batteries LCD Display Screen
    21 Multi-parameter Portable Water Analyzer LMS-PA100P Multi-parameter Portable Water Analyzer LMS-PA100P 220 mm × 120 mm × 100 mm Rechargeable lithium battery with 220V DC charging adapter LCD Display Screen
    22 Multi-parameter Touch-screen Online Analyzer LMS-OA200T Multi-parameter Touch-screen Online Analyzer LMS-OA200T 180 mm × 230 mm × 100 mm AC 220 VAC 7-inch Touch Screen
    more products
    Frequently Asked Questions (FAQ)
    Q What is the measurement principle of the TSS Analyzer?
    A The TSS Analyzer uses a 135° backlight scattering method, compliant with ISO7027 standards. Advanced optics measure the intensity of light scattered by suspended particles, enabling accurate and repeatable TSS and turbidity readings across diverse water matrices.
    Q What is the measurement range of the TSS Analyzer?
    A The analyzer supports two selectable ranges: 0–50,000 mg/L for standard applications and 0–120,000 mg/L for high-concentration environments such as sludge dewatering or industrial effluent streams.
    Q How does the self-cleaning mechanism work?
    A A motor-driven cleaning brush operates at user-programmable intervals to remove biofilm, algae, or sediment deposits from the optical window. This automated system ensures continuous, reliable measurements with minimal manual maintenance and zero downtime.
    Q Is the TSS Analyzer suitable for outdoor or submerged installation?
    A Yes. The sensor body is constructed from 316L stainless steel, offering excellent resistance to corrosive chemicals and high-pressure washdowns. It operates reliably across temperatures of -20°C to 60°C, making it suitable for submerged, outdoor, or harsh industrial environments.
    Q What communication protocol does the TSS Analyzer use?
    A The analyzer outputs data via RS-485 using the MODBUS protocol, enabling easy integration with PLCs, SCADA systems, data loggers, or online water quality monitoring platforms. It operates on 9–24 VDC power (12 VDC recommended).
    Q In which industries can the TSS Analyzer be applied?
    A The TSS Analyzer is widely used across industrial effluent management, municipal water treatment, environmental monitoring (rivers, lakes, coastal zones), aquaculture, mining and construction runoff control, and laboratory research. Its multi-parameter compensation ensures accurate results in both dynamic and stagnant water conditions.