Fluorescence DO Probe Meter - Trace Dissolved Oxygen Sensor from China Suppliers & Factory for Accurate Measurement
Product Parameters
| Product Name | Trace Dissolved Oxygen Sensor |
| Measurement Method | Fluorescent |
| Range | 0 – 2000 ppb | Temperature: 0 – 50℃ |
| Accuracy | ±1 ppb or 3% reading, whichever is greater |
| Voltage | 9 – 24 VDC (Recommend 12 VDC) |
| Material | Polymer Plastics |
| Size | 32 mm × 180 mm |
| Output | RS485, MODBUS Protocol |
| IP Grade | IP68 |
| Application | Boiler Water / Deaerated Water / Steam Condensate Water / Ultrapure Water |
Product Features
-
①Fluorescence Lifetime Technology Utilizes advanced oxygen-sensitive fluorescent materials for non-consumptive measurement, ensuring no electrolyte replacement or membrane maintenance.
-
②High Precision & Stability Achieves trace-level detection accuracy (±1 ppb) with minimal drift, ideal for ultra-low oxygen environments such as ultrapure water systems or pharmaceutical processes.
-
③Rapid Response Delivers real-time data with a response time under 60 seconds, enabling dynamic monitoring of dissolved oxygen fluctuations.
-
④Robust Construction IP68-rated polymer plastic housing resists corrosion, biofouling, and physical damage, suitable for harsh industrial or aquatic environments.
-
⑤Flexible Integration Compatible with portable analyzers for field use or online systems for continuous monitoring, supported by RS-485 and MODBUS protocol for seamless connectivity.
Application
1
Industrial Process Control
Ideal for monitoring trace dissolved oxygen in high-purity water systems used in semiconductor fabrication, pharmaceutical production, and power generation. Ensures strict quality control by detecting even minor DO fluctuations that could impact product integrity or equipment performance.
2
Environmental & Ecological Research
Facilitates precise measurement of trace DO in delicate aquatic ecosystems, such as wetlands, groundwater, or oligotrophic lakes. Helps researchers assess oxygen dynamics in low-DO environments critical to microbial activity and nutrient cycling.
3
Biotechnology & Microbiology
Supports bioreactor monitoring in cell culture, fermentation, and enzyme production processes, where trace DO levels directly affect microbial growth and metabolic efficiency. Enables real-time adjustments to maintain optimal conditions for bioprocess yields.
4
Water Quality Monitoring
Crucial for detecting trace DO in drinking water sources, especially in regions with strict regulatory standards. Also applicable to ultrapure water systems in laboratories or medical facilities, ensuring compliance with hygiene and safety requirements.
Digital RS485 Water Quality Sensors Technical Data
| Parameter | Model | Range | Accuracy |
| DO Sensor | LMS-DO10B | 0–20 mg/L, 0–60℃ | ±0.1–0.3 mg/L |
| DO Sensor | LMS-DO10C | 0–20 mg/L, 0–60℃ | ±0.3 mg/L |
| Trace DO Sensor | LMS-TDO100 | 0–2000 ppb, 0–50℃ | ±1 ppb |
| PH Sensor | LMS-PH100 | 0–14 pH | ±0.02 pH |
| ORP Sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV |
| EC/TDS Sensor | LMS-TDS102 | CT: 0–9999 uS/cm; 0–100 mS/cm TDS: 0–10000 ppm |
±2.5% FS |
| Salinity/EC/TDS Sensor | LMS-SAL104 | Conductivity: 0.1–500 mS/cm TDS: 0–60000 ppm Salinity: 0–500.00 ppt |
±1.5% FS |
| COD Sensor | LMS-COD100 | COD: 0.1–1500 mg/L TOC: 0.1–750 mg/L BOD: 0.1–900 mg/L Turbidity: 0.1–4000 NTU Temperature: 0–50℃ |
±5% equiv. KHP Temperature: ±0.5℃ |
| TSS Sensor | LMS-TSS100 | 0–50000 mg/L / 0–120000 mg/L | ±10% FS or 10 mg/L |
| Turbidity Sensor | LMS-TUR10L | 0–100 NTU | ±10% FS or 0.3 NTU |
| Turbidity Sensor | LMS-TUR10H | 0–3000 NTU | ±10% FS or 0.3 NTU |
| CO₂ Sensor | LMS-CO2100 | 2000 PPM / 10000 PPM / 50000 PPM | ±5% FS |
| Ammonia Nitrogen Sensor | LMS-NH4100 | 0–1000 mg/L | ±5% FS |
| Ion Selective Sensor | LMS-ION100 | 0–1000 mg/L | ±5% FS |
| Oil in Water Sensor | LMS-OIL100 | 0–50 mg/L; 0–5 mg/L | ±3% FS |
| Chlorophyll Sensor | LMS-CHL100 | 0–500 ug/L | ±3% FS |
| Blue-Green Algae Sensor | LMS-BGA100 | 0–2,000,000 cells/ml | ±3% FS |
| Residual Chlorine Sensor | LMS-HCLO100 | 0–20.00 ppm | ±5% FS |
| Marine Current Sensor | LMS-Current100 | Temperature: -3℃ – 45℃ Velocity of Flow: 0–500 cm/s Flow Direction: 0–359.9° |
±0.05℃ ±1 cm/s or ±2% ±2° |

Frequently Asked Questions
Q
What measurement method does the Trace Dissolved Oxygen Sensor use?The sensor uses fluorescence lifetime technology. It relies on oxygen-sensitive fluorescent materials that react to dissolved oxygen levels, enabling non-consumptive measurement without the need for electrolyte replacement or membrane maintenance.
Q
What is the detection range and accuracy of the LMS-TDO100?The LMS-TDO100 Trace DO Sensor has a measurement range of 0–2000 ppb with a temperature range of 0–50℃. Its accuracy is ±1 ppb or 3% of the reading, whichever is greater, making it suitable for ultra-low oxygen environments.
Q
Is the Trace Dissolved Oxygen Sensor suitable for outdoor or harsh environments?Yes. The sensor is rated IP68, meaning it is fully protected against dust and continuous water immersion. Its polymer plastic housing also resists corrosion and biofouling, making it reliable in harsh industrial and aquatic environments.
Q
What communication protocol does the sensor support?The sensor outputs data via RS485 using the MODBUS protocol, which enables easy integration into existing SCADA systems, PLCs, and online monitoring platforms. It supports both portable analyzers and continuous online monitoring setups.
Q
What are the typical applications for this trace DO sensor?This sensor is widely used in boiler water monitoring, deaerated water systems, steam condensate water testing, and ultrapure water quality control. It is also applied in semiconductor manufacturing, pharmaceutical production, biotechnology bioreactors, and environmental research.
Q
How does the Trace DO Sensor differ from a standard dissolved oxygen sensor?Unlike standard DO sensors that typically measure in the mg/L range, the Trace DO Sensor is designed for ultra-low concentration detection in the ppb (parts per billion) range (0–2000 ppb). This makes it far more sensitive and appropriate for applications where even minute oxygen levels can affect process quality or product integrity.