- Multi-parameter Water Analyzer
- Single-Parameter Water Aalyzer
- DO Sensor
- Trace DO Sensor
- CO₂ Sensor
- COD Sensor
- EC TDS Sensor
- Salinity EC TDS Sensor
- TSS Sensor
- Turbidity Sensor
- PH Sensor
- ORP
- Ion Selective Sensor
- Ammonia Nitrogen Sensor
- Oil in Water Sensor
- Blue-Green Algae Sensor
- Chlorophyll Sensor
- Residual Chlorine Sensor
- Marine Current Sensor
High-Accuracy RS485 Ion Selective Sensor for Water Quality - Eco-Friendly, Reliable Data | China Suppliers & Factory
| Product Name | Ion Selective Sensor |
| Measurement Method | Ionic electrode |
| Range | 0 ~ 1000 mg/L |
| Accuracy | ±5% F.S. |
| Power | 9–24 VDC (Recommend 12 VDC) |
| Material | Polymer Plastic |
| Size | 31mm × 200mm |
| Working Temperature | 0–50 ℃ |
| Cable Length | 5m, can be extended according to user need |
| Sensor Interface Supports | RS-485, MODBUS protocol |
-
♻️① Eco-Friendly & Pollution-Resistant DesignConstructed from robust polymer plastic, the sensor resists chemical corrosion and physical wear, making it ideal for harsh industrial or outdoor environments.
-
⚙️② Flexible Calibration SolutionsSupports custom standard liquid calibration with forward and reverse curve adjustments to meet diverse measurement scenarios.
-
🔬③ Multi-Ion Detection CapabilityCompatible with critical ions like NH4+, NO3-, K+, and Ca²+, enabling tailored applications in wastewater treatment, agriculture, and environmental monitoring.
-
⚡④ Isolated Power Supply & Anti-InterferenceEnsures stable data transmission and minimal noise, even in electromagnetically noisy environments.
-
🔧⑤ Easy Integration & MaintenanceCompact design and direct installation compatibility simplify deployment into existing water quality monitoring systems.
-
🌍⑥ Wide Application ScopePerforms reliably in surface water, sewage, drinking water, and industrial effluent testing with minimal maintenance.
-
🏭 1. Municipal Wastewater TreatmentMonitor ion concentrations (e.g., ammonium, nitrate) to optimize treatment processes and comply with discharge standards.
-
🌿 2. Environmental ProtectionTrack pollutants in rivers, lakes, and reservoirs to assess ecological health and pollution sources.
-
🌾 3. Agricultural Water ManagementMeasure nutrient ions (K+, Ca²+) in irrigation systems to enhance crop yield and soil quality.
-
🏗️ 4. Industrial Process ControlEnsure precise ion levels in chemical manufacturing, food production, and pharmaceutical processes.
-
💧 5. Drinking Water SafetyDetect harmful ions in potable water sources to safeguard public health.
-
🐟 6. Aquaculture SystemsMaintain optimal ion balance for aquatic species health and growth.
| Parameter | Model | Range | Accuracy |
| DO sensor | LMS-DO10B | 0–20 mg/L, 0–60 ℃ | ±0.1–0.3 mg/L |
| DO sensor | LMS-DO10C | 0–20 mg/L, 0–60 ℃ | ±0.3 mg/L |
| Trace DO sensor | LMS-TDO100 | 0–2000 ppb, 0–50 ℃ | ±1 ppb |
| PH sensor | LMS-PH100 | 0–14 pH | ±0.02 pH |
| ORP sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV |
| EC/TDS sensor | LMS-TDS102 | CT: 0–9999 uS/cm; 0–100 mS/cm; TDS: 0–10000 ppm |
±2.5% FS |
| Salinity/EC/TDS sensor | LMS-SAL104 | Conductivity: 0.1–500 mS/cm TDS: 0–60000 ppm Salinity: 0–500.00 ppt |
±1.5% FS |
| COD sensor | LMS-COD100 | COD: 0.1–1500 mg/L TOC: 0.1–750 mg/L BOD: 0.1–900 mg/L Turbidity: 0.1–4000 NTU Temperature: 0–50 ℃ |
±5% equiv. KHP Temperature: ±0.5 ℃ |
| TSS sensor | LMS-TSS100 | 0–50000 mg/L / 0–120000 mg/L | ±10% FS or 10 mg/L |
| Turbidity sensor | LMS-TUR10L | 0–100 NTU | ±10% FS or 0.3 NTU |
| Turbidity sensor | LMS-TUR10H | 0–3000 NTU | ±10% FS or 0.3 NTU |
| CO2 sensor | LMS-CO2100 | 2000 PPM / 10000 PPM / 50000 PPM | ±5% FS |
| Ammonia Nitrogen sensor | LMS-NH4100 | 0–1000 mg/L | ±5% FS |
| Ion Selective sensor | LMS-ION100 | 0–1000 mg/L | ±5% FS |
| Oil in Water sensor | LMS-OIL100 | 0–50 mg/L; 0–5 mg/L | ±3% FS |
| Chlorophyll sensor | LMS-CHL100 | 0–500 ug/L | ±3% FS |
| Blue-Green Algae sensor | LMS-BGA100 | 0–2,000,000 cells/ml | ±3% FS |
| Residual Chlorine sensor | LMS-HCLO100 | 0–20.00 ppm | ±5% FS |
| Marine Current sensor | LMS-Current100 | Temperature: -3 ℃ – 45 ℃ Velocity of flow: 0–500 cm/s Flow direction: 0–359.9° |
±0.05 ℃ ±1 cm/s or ±2% ±2° |
| Product Name | Ion Selective Sensor |
| Measurement method | Ionic electrode |
| Range | 0 ~ 1000 mg/L |
| Accuracy | ±5%F.S. |
| Power | 9-24VDC(Recommend 12 VDC) |
| Material | Polymer Plastic |
| Size | 31mm × 200mm |
| Working Temperature | 0–50℃ |
| Cable length | 5m, can be extended according to user need |
| Sensor Interface Supports | RS-485, MODBUS protocol |
Constructed from robust polymer plastic, the sensor resists chemical corrosion and physical wear, making it ideal for harsh industrial or outdoor environments.
Supports custom standard liquid calibration with forward and reverse curve adjustments to meet diverse measurement scenarios.
Compatible with critical ions like NH4+, NO3-, K+, and Ca²+, enabling tailored applications in wastewater treatment, agriculture, and environmental monitoring.
Ensures stable data transmission and minimal noise, even in electromagnetically noisy environments.
Compact design and direct installation compatibility simplify deployment into existing water quality monitoring systems.
Performs reliably in surface water, sewage, drinking water, and industrial effluent testing with minimal maintenance.
Monitor ion concentrations (e.g., ammonium, nitrate) to optimize treatment processes and comply with discharge standards.
Track pollutants in rivers, lakes, and reservoirs to assess ecological health and pollution sources.
Measure nutrient ions (K+, Ca²+) in irrigation systems to enhance crop yield and soil quality.
Ensure precise ion levels in chemical manufacturing, food production, and pharmaceutical processes.
Detect harmful ions in potable water sources to safeguard public health.
Maintain optimal ion balance for aquatic species health and growth.
| Parameter | Model | Range | Accuracy |
| DO sensor | LMS-DO10B | 0-20mg/L, 0-60℃ | ±0.1-0.3mg/L |
| DO sensor | LMS-DO10C | 0-20mg/L, 0-60℃ | ±0.3mg/L |
| Trace DO sensor | LMS-TDO100 | 0-2000ppb, 0-50℃ | ±1ppb |
| PH sensor | LMS-PH100 | 0-14pH | ±0.02pH |
| ORP sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV |
| EC/TDS sensor | LMS-TDS102 | CT: 0-9999uS/cm; 0-100mS/cm; TDS: 0-10000ppm |
±2.5%FS |
| Salinity/EC/TDS sensor | LMS-SAL104 | Conductivity: 0.1-500 mS/cm TDS: 0-60000ppm Salinity: 0-500.00ppt |
±1.5%FS |
| COD sensor | LMS-COD100 | COD: 0.1-1500mg/L TOC: 0.1-750mg/L BOD: 0.1-900mg/L Turbidity: 0.1-4000NTU Temperature: 0-50℃ |
±5% equiv.KHP Temperature: ±0.5℃ |
| TSS sensor | LMS-TSS100 | 0-50000mg/L / 0-120000mg/L | ±10%FS or 10 mg/L |
| Turbidity sensor | LMS-TUR10L | 0-100NTU | ±10%FS or 0.3 NTU |
| Turbidity sensor | LMS-TUR10H | 0-3000NTU | ±10%FS or 0.3 NTU |
| CO2 sensor | LMS-CO2100 | 2000PPM / 10000PPM / 50000PPM | ±5%FS |
| Ammonia Nitrogen sensor | LMS-NH4100 | 0-1000 mg/L | ±5%FS |
| Ion Selective sensor | LMS-ION100 | 0-1000 mg/L | ±5%FS |
| Oil in Water sensor | LMS-OIL100 | 0-50 mg/L; 0-5 mg/L | ±3%FS |
| Chlorophyll sensor | LMS-CHL100 | 0-500ug/L | ±3%FS |
| Blue-Green Algae sensor | LMS-BGA100 | 0-2,000,000 cells/ml | ±3%FS |
| Residual Chlorine sensor | LMS-HCLO100 | 0-20.00 ppm | ±5%FS |
| Marine Current sensor | LMS-Current100 | Temperature: -3℃ – 45℃ Velocity of flow: 0-500 cm/s Flow direction: 0-359.9° |