This high-precision residual chlorine sensor from leading China suppliers features a three-electrode constant potential design that provides precise, real-time measurements of free chlorine (ClO⁻/HClO) in various water systems. Boasting a wide measurement range of 0-20.00 ppm and ultra-fine resolution down to 0.001 ppm, this sensor is essential for ensuring drinking water safety, maintaining industrial effluent compliance, and managing aquaculture systems effectively. Designed by an innovative factory, this sensor includes pH compensation to reduce measurement drift and supports Modbus RTU over RS485 for smooth integration into SCADA, IoT, or industrial control systems. Housed in a robust, IP68-rated casing with G3/4 thread options, it allows for versatile installation in both flow-through and submerged settings. With features like automatic calibration commands and an optional self-cleaning electrode cover, this sensor guarantees long-term stability and minimizes maintenance needs. Trust in our China-manufactured solutions for reliable water quality monitoring

    Product Parameters
    Product Name Residual Chlorine Sensor
    Model LMS-HCLO100
    Range Residual chlorine meter: 0 – 20.00 ppm
    Temperature: 0 – 50.0 ℃
    Accuracy Residual chlorine meter: ± 5.0% F.S, supporting pH compensation function
    Temperature: ±0.5 ℃
    Power 6VDC – 30VDC
    Material Polymer Plastic
    Warranty Period Electrode head 12 months / Digital board 12 months
    Sensor Interface Supports RS-485, MODBUS protocol
    Cable Length 5m, can be extended according to user need
    Application Tap water treatment, swimming pool water quality monitoring, and industrial wastewater treatment.
    Product Features
    Three-Electrode Constant Potential Technology
    Ensures stable measurements by minimizing polarization effects and interference from pH fluctuations, even in dynamic water conditions.
    Multi-Range Resolution & pH Compensation
    Supports resolutions from 0.001 ppm to 0.1 ppm and automatic pH compensation to enhance accuracy in varying water chemistries.
    Modbus RTU Integration
    Pre-configured with default address (0x01) and baud rate (9600 N81), enabling plug-and-play connectivity to industrial automation systems.
    Robust Design for Harsh Environments
    IP68-rated housing and corrosion-resistant electrodes withstand prolonged submersion, high-pressure flows, and temperatures up to 60℃.
    Low Maintenance & Self-Diagnostics
    Features automatic zero/slope calibration commands, error code feedback, and optional protective covers to reduce biofouling and manual upkeep.
    Application
    1
    Drinking Water Treatment
    Monitor residual chlorine levels in real time to ensure disinfection efficacy and regulatory compliance.
    2
    Industrial Wastewater Management
    Track chlorine concentrations in effluents to meet environmental discharge standards and avoid penalties.
    3
    Aquaculture Systems
    Prevent over-chlorination in fish farms to protect aquatic life and optimize water quality.
    4
    Swimming Pool & Spa Safety
    Maintain safe chlorine levels for public health while avoiding corrosive over-dosing.
    5
    Smart City Water Networks
    Integrate into IoT-based water quality monitoring systems for urban infrastructure management.
    application
    Digital RS485 Water Quality Sensors Technical Data
    Parameter Model Range Accuracy
    DO sensor LMS-DO10B 0-20mg/L, 0-60℃ ±0.1-0.3mg/L
    DO sensor LMS-DO10C 0-20mg/L, 0-60℃ ±0.3mg/L
    Trace DO sensor LMS-TDO100 0-2000ppb, 0-50℃ ±1ppb
    PH sensor LMS-PH100 0-14pH ±0.02pH
    ORP sensor LMS-ORP100 ±1000.0 mV ±0.2 mV
    EC/TDS sensor LMS-TDS102 CT: 0-9999uS/cm; 0-100mS/cm;
    TDS: 0-10000ppm
    ±2.5%FS
    Salinity/EC/TDS sensor LMS-SAL104 Conductivity: 0.1-500 mS/cm
    TDS: 0-60000ppm
    Salinity: 0-500.00ppt
    ±1.5%FS
    COD sensor LMS-COD100 COD: 0.1-1500mg/L
    TOC: 0.1-750mg/L
    BOD: 0.1-900mg/L
    Turbidity: 0.1-4000NTU
    Temperature: 0-50℃
    ±5% equiv.KHP
    Temperature: ±0.5℃
    TSS sensor LMS-TSS100 0-50000mg/L / 0-120000mg/L ±10%FS or 10 mg/L
    Turbidity sensor LMS-TUR10L 0-100NTU ±10%FS or 0.3 NTU
    Turbidity sensor LMS-TUR10H 0-3000NTU ±10%FS or 0.3 NTU
    CO2 sensor LMS-CO2100 2000PPM / 10000PPM / 50000PPM ±5%FS
    Ammonia Nitrogen sensor LMS-NH4100 0-1000 mg/L ±5%FS
    Ion Selective sensor LMS-ION100 0-1000 mg/L ±5%FS
    Oil in Water sensor LMS-OIL100 0-50 mg/L; 0-5 mg/L ±3%FS
    Chlorophyll sensor LMS-CHL100 0-500ug/L ±3%FS
    Blue-Green Algae sensor LMS-BGA100 0-2000,000 cells/ml ±3%FS
    Residual Chlorine sensor LMS-HCLO100 0 - 20.00 ppm ±5%FS
    Marine Current sensor LMS-Current100 Temperature: -3℃ - 45℃
    Velocity of flow: 0-500 cm/s
    Flow direction: 0-359.9°
    ±0.05℃
    ±1 cm/s or ±2%
    ±2°
    more products
    Frequently Asked Questions (FAQ)
    Q
    What is the measurement range of the LMS-HCLO100 Residual Chlorine Sensor?
    A
    The LMS-HCLO100 measures residual chlorine from 0 to 20.00 ppm and temperature from 0 to 50.0℃, making it suitable for a wide range of water quality monitoring applications.
    Q
    What communication protocol does the Residual Chlorine Sensor support?
    A
    The sensor supports RS-485 interface with Modbus RTU protocol, pre-configured with default address 0x01 and baud rate 9600 N81, allowing easy integration into industrial automation and IoT systems.
    Q
    Is the LMS-HCLO100 suitable for outdoor or submerged installation?
    A
    Yes. The sensor features an IP68-rated housing with corrosion-resistant electrodes, enabling prolonged submersion and operation in high-pressure flow environments and temperatures up to 60℃.
    Q
    Does the sensor support pH compensation for accurate readings?
    A
    Yes. The LMS-HCLO100 includes an automatic pH compensation function and supports multiple resolution levels from 0.001 ppm to 0.1 ppm, ensuring accurate readings across varying water chemistries.
    Q
    How long is the cable and can it be extended?
    A
    The standard cable length is 5 meters. It can be extended according to user requirements to accommodate various installation distances and site conditions.
    Q
    What maintenance is required for the LMS-HCLO100 sensor?
    A
    The sensor is designed for low maintenance with automatic zero/slope calibration commands and built-in error code feedback. Optional protective covers are available to reduce biofouling and minimize manual upkeep over time.