This advanced residual chlorine sensor, manufactured in China, features a three-electrode constant potential design that ensures high precision in measuring free chlorine (ClO⁻/HClO) in various water systems. With a broad measurement range of 0-20.00 ppm and impressive resolution capabilities down to 0.001 ppm, this sensor is ideal for monitoring drinking water safety, ensuring industrial effluent compliance, and managing aquaculture systems. As a leading supplier, we integrate pH compensation technology to reduce measurement drift and offer seamless compatibility with SCADA, IoT, or industrial control systems via Modbus RTU over RS48Housed in a robust, IP68-rated enclosure with G3/4 thread options, it provides versatile installation for both flow-through and submerged setups. Automatic calibration commands and an optional self-cleaning electrode cover enhance long-term stability and minimize maintenance, making it a reliable choice for both suppliers and factories seeking efficient water quality solutions

    Product Parameters
    Product Name Residual Chlorine Sensor
    Model LMS-HCLO100
    Range Residual chlorine meter: 0 – 20.00 ppm
    Temperature: 0 – 50.0℃
    Accuracy Residual chlorine meter: ±5.0% F.S, supporting pH compensation function
    Temperature: ±0.5℃
    Power 6VDC – 30VDC
    Material Polymer Plastic
    Warranty Period Electrode head 12 months / Digital board 12 months
    Sensor Interface Supports RS-485, MODBUS protocol
    Cable Length 5m, can be extended according to user need
    Application Tap water treatment, swimming pool water quality monitoring, and industrial wastewater treatment.
    Product Features
    • Three-Electrode Constant Potential Technology
      Ensures stable measurements by minimizing polarization effects and interference from pH fluctuations, even in dynamic water conditions.
    • Multi-Range Resolution & pH Compensation
      Supports resolutions from 0.001 ppm to 0.1 ppm and automatic pH compensation to enhance accuracy in varying water chemistries.
    • Modbus RTU Integration
      Pre-configured with default address (0x01) and baud rate (9600 N81), enabling plug-and-play connectivity to industrial automation systems.
    • Robust Design for Harsh Environments
      IP68-rated housing and corrosion-resistant electrodes withstand prolonged submersion, high-pressure flows, and temperatures up to 60℃.
    • Low Maintenance & Self-Diagnostics
      Features automatic zero/slope calibration commands, error code feedback, and optional protective covers to reduce biofouling and manual upkeep.
    Application
    • 💧
      1. Drinking Water Treatment
      Monitor residual chlorine levels in real time to ensure disinfection efficacy and regulatory compliance.
    • 🏭
      2. Industrial Wastewater Management
      Track chlorine concentrations in effluents to meet environmental discharge standards and avoid penalties.
    • 🐟
      3. Aquaculture Systems
      Prevent over-chlorination in fish farms to protect aquatic life and optimize water quality.
    • 🏊
      4. Swimming Pool & Spa Safety
      Maintain safe chlorine levels for public health while avoiding corrosive over-dosing.
    • 🌐
      5. Smart City Water Networks
      Integrate into IoT-based water quality monitoring systems for urban infrastructure management.
    application
    Digital RS485 Water Quality Sensors Technical Data
    Parameter Model Range Accuracy
    DO sensor LMS-DO10B 0–20mg/L, 0–60℃ ±0.1–0.3mg/L
    DO sensor LMS-DO10C 0–20mg/L, 0–60℃ ±0.3mg/L
    Trace DO sensor LMS-TDO100 0–2000ppb, 0–50℃ ±1ppb
    PH sensor LMS-PH100 0–14pH ±0.02pH
    ORP sensor LMS-ORP100 ±1000.0 mV ±0.2 mV
    EC/TDS sensor LMS-TDS102 CT: 0–9999uS/cm; 0–100mS/cm;
    TDS: 0–10000ppm
    ±2.5%FS
    Salinity/EC/TDS sensor LMS-SAL104 Conductivity: 0.1–500 mS/cm
    TDS: 0–60000ppm
    Salinity: 0–500.00ppt
    ±1.5%FS
    COD sensor LMS-COD100 COD: 0.1–1500mg/L
    TOC: 0.1–750mg/L
    BOD: 0.1–900mg/L
    Turbidity: 0.1–4000NTU
    Temperature: 0–50℃
    ±5% equiv.KHP
    Temperature: ±0.5℃
    TSS sensor LMS-TSS100 0–50000mg/L / 0–120000mg/L ±10%FS or 10 mg/L
    Turbidity sensor LMS-TUR10L 0–100NTU ±10%FS or 0.3 NTU
    Turbidity sensor LMS-TUR10H 0–3000NTU ±10%FS or 0.3 NTU
    CO2 sensor LMS-CO2100 2000PPM / 10000PPM / 50000PPM ±5%FS
    Ammonia Nitrogen sensor LMS-NH4100 0–1000 mg/L ±5%FS
    Ion Selective sensor LMS-ION100 0–1000 mg/L ±5%FS
    Oil in Water sensor LMS-OIL100 0–50 mg/L; 0–5 mg/L ±3%FS
    Chlorophyll sensor LMS-CHL100 0–500ug/L ±3%FS
    Blue-Green Algae sensor LMS-BGA100 0–2,000,000 cells/ml ±3%FS
    Residual Chlorine sensor LMS-HCLO100 0–20.00 ppm ±5%FS
    Marine Current sensor LMS-Current100 Temperature: -3℃ – 45℃
    Velocity of flow: 0–500 cm/s
    Flow direction: 0–359.9°
    ±0.05℃
    ±1 cm/s or ±2%
    ±2°
    more products
    Frequently Asked Questions (FAQ)
    Q What is the measurement range of the LMS-HCLO100 Residual Chlorine Sensor?
    A The LMS-HCLO100 measures residual chlorine in the range of 0–20.00 ppm and temperature in the range of 0–50.0℃, making it suitable for a wide variety of water treatment applications.
    Q What communication protocol does the residual chlorine sensor support?
    A The sensor supports RS-485 interface with Modbus RTU protocol (default address 0x01, baud rate 9600 N81), enabling seamless integration with industrial automation and IoT systems.
    Q Is the LMS-HCLO100 suitable for outdoor or submerged installation?
    A Yes. The sensor features an IP68-rated housing with corrosion-resistant electrodes, making it capable of prolonged submersion, resistance to high-pressure flows, and operation in temperatures up to 60℃.
    Q How does the sensor handle pH interference in measurements?
    A The LMS-HCLO100 uses three-electrode constant potential technology and supports automatic pH compensation, which minimizes the impact of pH fluctuations and ensures accurate residual chlorine readings across varying water chemistries.
    Q What maintenance is required for the residual chlorine sensor?
    A The sensor is designed for low maintenance with automatic zero/slope calibration commands and built-in self-diagnostic error code feedback. Optional protective covers are also available to reduce biofouling and minimize manual upkeep.
    Q Can the cable length be customized for specific installation requirements?
    A The standard cable length is 5 meters, but it can be extended according to the user's specific needs, providing flexibility for various installation environments such as deep tanks, remote pipelines, or large treatment facilities.

    Leave Your Message

    AI Helps Write