• instagram (5)
  • 65e82dd72e92827394
  • 65e82dd7a74e048637
  • 65e82dd83039430728
Leave Your Message

High-Precision Digital Residual Chlorine Sensor from China Factory | Reliable Water Quality Monitoring Suppliers

Discover our high-precision residual chlorine sensor, designed with a robust three-electrode constant potential technology for accurate, real-time measurements of free chlorine (ClO⁻/HClO) in various water systems. This advanced sensor boasts an extensive measurement range of 0-20.00 ppm and exceptional resolution down to 0.001 ppm, making it an ideal choice for ensuring drinking water safety, complying with industrial effluent regulations, and managing aquaculture practices, Manufactured in China, our sensor includes integrated pH compensation to minimize measurement drift, and supports Modbus RTU over RS485 for easy integration into SCADA, IoT, or industrial control systems. Housed in a durable, IP68-rated enclosure with G3/4 thread options, it provides flexible installation for either flow-through or submerged applications, Additionally, the sensor features automatic calibration commands and an optional self-cleaning electrode cover to enhance long-term stability and reduce maintenance efforts. As a reliable supplier and factory of cutting-edge sensors, we ensure high-quality products to meet your water quality monitoring needs

    Product Parameters
    Product Name Residual Chlorine Sensor
    Model LMS-HCLO100
    Range Residual chlorine meter: 0 – 20.00 ppm
    Temperature: 0 – 50.0℃
    Accuracy Residual chlorine meter: ±5.0% F.S, supporting pH compensation function
    Temperature: ±0.5℃
    Power 6VDC – 30VDC
    Material Polymer Plastic
    Warranty Period Electrode head 12 months / Digital board 12 months
    Sensor Interface Supports RS-485, MODBUS protocol
    Cable Length 5m, can be extended according to user need
    Application Tap water treatment, swimming pool water quality monitoring, and industrial wastewater treatment.
    Product Features
    Three-Electrode Constant Potential Technology
    Ensures stable measurements by minimizing polarization effects and interference from pH fluctuations, even in dynamic water conditions.
    Multi-Range Resolution & pH Compensation
    Supports resolutions from 0.001 ppm to 0.1 ppm and automatic pH compensation to enhance accuracy in varying water chemistries.
    Modbus RTU Integration
    Pre-configured with default address (0x01) and baud rate (9600 N81), enabling plug-and-play connectivity to industrial automation systems.
    Robust Design for Harsh Environments
    IP68-rated housing and corrosion-resistant electrodes withstand prolonged submersion, high-pressure flows, and temperatures up to 60℃.
    Low Maintenance & Self-Diagnostics
    Features automatic zero/slope calibration commands, error code feedback, and optional protective covers to reduce biofouling and manual upkeep.
    Application
    1
    Drinking Water Treatment
    Monitor residual chlorine levels in real time to ensure disinfection efficacy and regulatory compliance.
    2
    Industrial Wastewater Management
    Track chlorine concentrations in effluents to meet environmental discharge standards and avoid penalties.
    3
    Aquaculture Systems
    Prevent over-chlorination in fish farms to protect aquatic life and optimize water quality.
    4
    Swimming Pool & Spa Safety
    Maintain safe chlorine levels for public health while avoiding corrosive over-dosing.
    5
    Smart City Water Networks
    Integrate into IoT-based water quality monitoring systems for urban infrastructure management.
    application
    Digital RS485 Water Quality Sensors Technical Data
    Parameter Model Range Accuracy
    DO Sensor LMS-DO10B 0–20 mg/L, 0–60℃ ±0.1–0.3 mg/L
    DO Sensor LMS-DO10C 0–20 mg/L, 0–60℃ ±0.3 mg/L
    Trace DO Sensor LMS-TDO100 0–2000 ppb, 0–50℃ ±1 ppb
    pH Sensor LMS-PH100 0–14 pH ±0.02 pH
    ORP Sensor LMS-ORP100 ±1000.0 mV ±0.2 mV
    EC/TDS Sensor LMS-TDS102 CT: 0–9999 uS/cm; 0–100 mS/cm
    TDS: 0–10000 ppm
    ±2.5% FS
    Salinity/EC/TDS Sensor LMS-SAL104 Conductivity: 0.1–500 mS/cm
    TDS: 0–60000 ppm
    Salinity: 0–500.00 ppt
    ±1.5% FS
    COD Sensor LMS-COD100 COD: 0.1–1500 mg/L
    TOC: 0.1–750 mg/L
    BOD: 0.1–900 mg/L
    Turbidity: 0.1–4000 NTU
    Temperature: 0–50℃
    ±5% equiv. KHP
    Temperature: ±0.5℃
    TSS Sensor LMS-TSS100 0–50000 mg/L / 0–120000 mg/L ±10% FS or 10 mg/L
    Turbidity Sensor LMS-TUR10L 0–100 NTU ±10% FS or 0.3 NTU
    Turbidity Sensor LMS-TUR10H 0–3000 NTU ±10% FS or 0.3 NTU
    CO₂ Sensor LMS-CO2100 2000 PPM / 10000 PPM / 50000 PPM ±5% FS
    Ammonia Nitrogen Sensor LMS-NH4100 0–1000 mg/L ±5% FS
    Ion Selective Sensor LMS-ION100 0–1000 mg/L ±5% FS
    Oil in Water Sensor LMS-OIL100 0–50 mg/L; 0–5 mg/L ±3% FS
    Chlorophyll Sensor LMS-CHL100 0–500 ug/L ±3% FS
    Blue-Green Algae Sensor LMS-BGA100 0–2,000,000 cells/ml ±3% FS
    Residual Chlorine Sensor LMS-HCLO100 0–20.00 ppm ±5% FS
    Marine Current Sensor LMS-Current100 Temperature: -3℃ – 45℃
    Velocity of flow: 0–500 cm/s
    Flow direction: 0–359.9°
    ±0.05℃
    ±1 cm/s or ±2%
    ±2°
    more products
    Frequently Asked Questions
    Q What is the measurement range of the LMS-HCLO100 Residual Chlorine Sensor?
    A The LMS-HCLO100 measures residual chlorine in the range of 0 to 20.00 ppm, and simultaneously monitors water temperature from 0 to 50.0℃.
    Q Does the residual chlorine sensor support pH compensation?
    A Yes. The sensor supports automatic pH compensation, which helps maintain measurement accuracy of ±5.0% F.S even when water chemistry varies.
    Q What communication protocol does the LMS-HCLO100 use?
    A The sensor uses RS-485 with Modbus RTU protocol. It comes pre-configured with a default address of 0x01 and a baud rate of 9600 N81, allowing easy plug-and-play integration with industrial automation systems.
    Q Is the residual chlorine sensor suitable for outdoor or submerged use?
    A Yes. The sensor features an IP68-rated housing with corrosion-resistant electrodes, making it suitable for prolonged submersion, high-pressure flow environments, and temperatures up to 60℃.
    Q How long is the cable and can it be extended?
    A The standard cable length is 5 meters. It can be extended according to user requirements to accommodate various installation scenarios.
    Q What are the typical applications for the LMS-HCLO100?
    A The sensor is widely used in drinking water treatment, industrial wastewater management, aquaculture systems, swimming pool and spa safety monitoring, and smart city IoT-based water quality networks.