Product Parameters
| Product Name | ORP sensor |
| Model | LMS-ORP100 |
| Measurement Method | Ionic Electrode |
| Range | ±1000.0 mV |
| Accuracy | 0.1 mV |
| Power | 9–24 VDC (Recommended: 12 VDC) |
| Voltage | 8–24 VDC (55 mA / 12V) |
| Material | Polymer Plastic |
| Size | 31 mm × 140 mm |
| Output | RS-485, MODBUS Protocol |
Product Features
①
High-Accuracy ORP Measurement
Employs an advanced ionic electrode method to deliver precise and stable ORP readings up to ±1000.0 mV with a resolution of 0.1 mV.
②
Robust and Compact Design
Constructed with polymer plastic and a flat bubble structure, the sensor is durable, easy to clean, and resistant to damage.
③
Temperature Compensation Support
Allows both automatic and manual temperature compensation for improved accuracy under varying environmental conditions.
④
Modbus RTU Communication
Integrated RS485 interface supports the Modbus RTU protocol, enabling seamless integration with data loggers and control systems.
⑤
Anti-Interference and Stable Performance
Features an isolated power supply design that ensures data stability and strong anti-interference capability in noisy electrical environments.

Applications
Industrial Wastewater Treatment
In chemical, electroplating, or printing and dyeing industries, the sensor monitors ORP during wastewater oxidation/reduction processes (e.g., removing heavy metals or organic pollutants). It helps operators confirm whether the reaction is complete (e.g., sufficient oxidant dosage) and ensures treated wastewater meets discharge standards, reducing environmental pollution.
Aquaculture Water Quality Management
In fish, shrimp, or shellfish farms (especially recirculating aquaculture systems), ORP reflects the level of organic matter and dissolved oxygen in water. Low ORP often indicates poor water quality and high disease risk. The sensor provides real-time data, allowing farmers to adjust aeration or add microbial agents timely, maintaining a healthy aquatic environment and improving breeding survival rates.
Environmental Water Quality Monitoring
For surface water (rivers, lakes, reservoirs) and groundwater, the sensor measures ORP to assess ecological health and pollution status. For example, abnormal ORP fluctuations may indicate sewage inflow; long-term data tracking can also evaluate the effectiveness of ecological restoration projects (e.g., lake eutrophication control), providing support for environmental protection departments.
Drinking Water Safety Supervision
In water treatment plants, the sensor is used in raw water pretreatment, disinfection (chlorine or ozone disinfection), and finished water storage. It ensures disinfection is thorough (sufficient oxidation to inactivate pathogens) while avoiding excessive disinfectant residues (which affect taste or produce harmful by-products). It also supports real-time monitoring of tap water pipelines, safeguarding end-user drinking water safety.
Laboratory Scientific Research
In environmental science, aquatic ecology, or water chemistry laboratories, the sensor provides high-precision ORP data for experiments. For example, it can analyze the oxidation behavior of pollutants, study the relationship between temperature/pH and ORP, or verify new water treatment technologies—supporting the development of scientific theories and practical applications.
Swimming Pool & Recreational Water Maintenance
In public swimming pools, water parks, or spas, ORP (typically 650–750 mV) is a key indicator of disinfection effectiveness. The sensor monitors ORP continuously, enabling automatic adjustment of chlorine dosage. This reduces manual monitoring efforts and prevents bacterial growth (e.g., Legionella), ensuring a safe and hygienic water environment for users.

Digital RS485 Water Quality Sensors Technical Data
| Digital RS485 Water Quality Sensors Technical Data | ||||||
| No. | Picture | Product Name | Model | Range | Accuracy | Resolution |
|---|---|---|---|---|---|---|
| 1 | ![]() |
DO sensor | LMS-DO10B | 0–20 mg/L, 0–60℃ | ±0.1–0.3 mg/L | 0.01 mg/L |
| 2 | ![]() |
DO sensor | LMS-DO10C | 0–20 mg/L, 0–60℃ | ±0.3 mg/L | 0.01 mg/L |
| 3 | ![]() |
Trace DO sensor | LMS-TDO100 | 0–2000 ppb, 0–50℃ | ±1 ppb | 1 ppb |
| 4 | ![]() |
PH sensor | LMS-PH100 | 0–14 pH | ±0.02 pH | 0.01 pH |
| 5 | ![]() |
ORP sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV | 0.1 mV |
| 6 | ![]() |
EC/TDS sensor | LMS-TDS102 | CT: 0–9999 uS/cm; 0–100 mS/cm; TDS: 0–10000 ppm | ±2.5% FS | 1 uS/cm, 0.01 mS/cm, 1 ppm |
| 7 | ![]() |
Salinity/EC/TDS sensor | LMS-SAL104 | Conductivity: 0.1–500 mS/cm; TDS: 0–60000 ppm; Salinity: 0–500.00 ppt | ±1.5% FS | 1 uS/cm, 0.01 mS/cm, 1 ppm, 0.01 ppt |
| 8 | ![]() |
COD sensor | LMS-COD100 | COD: 0.1–1500 mg/L; TOC: 0.1–750 mg/L; BOD: 0.1–900 mg/L; Turbidity: 0.1–4000 NTU; Temp: 0–50℃ | ±5% equiv. KHP; Temp: ±0.5℃ | 0.01 mg/L equiv. KHP |
| 9 | ![]() |
TSS sensor | LMS-TSS100 | 0–50000 mg/L / 0–120000 mg/L | ±10% FS or 10 mg/L | 0.1 mg/L or 1 mg/L |
| 10 | ![]() |
Turbidity sensor | LMS-TUR10L | 0–100 NTU | ±10% FS or 0.3 NTU | 0.01 NTU |
| 11 | ![]() |
Turbidity sensor | LMS-TUR10H | 0–3000 NTU | ±10% FS or 0.3 NTU | 0.01 NTU |
| 12 | ![]() |
CO2 sensor | LMS-CO2100 | 2000 PPM / 10000 PPM / 50000 PPM | ±5% FS | 1 ppm |
| 13 | ![]() |
Ammonia Nitrogen sensor | LMS-NH4100 | 0–1000 mg/L | ±5% FS | — |
| 14 | ![]() |
Ion Selective sensor | LMS-ION100 | 0–1000 mg/L | ±5% FS | — |
| 15 | ![]() |
Oil in Water sensor | LMS-OIL100 | 0–50 mg/L; 0–5 mg/L | ±3% FS | 0.01 ppm |
| 16 | ![]() |
Chlorophyll sensor | LMS-CHL100 | 0–500 ug/L | ±3% FS | 0.1 ug/L |
| 17 | ![]() |
Blue-Green Algae sensor | LMS-BGA100 | 0–2,000,000 cells/ml | ±3% FS | — |
| 18 | ![]() |
Residual Chlorine sensor | LMS-HCLO100 | 0–20.00 ppm | ±5% FS | 0.001 / 0.01 ppm |
| 19 | ![]() |
Marine Current sensor | LMS-Current100 | Temp: -3℃–45℃; Velocity: 0–500 cm/s; Direction: 0–359.9° | ±0.05℃; ±1 cm/s or ±2%; ±2° | Temp: 0.001℃; Velocity: 0.1 cm/s; Direction: 0.1° |
| Water Quality Analyzer Equipment | ||||||
| No. | Picture | Product Name | Model | Size | Power | Display Output |
| 20 | ![]() |
Portable DO Analyzer | LMS-PA100 | 100 mm × 204 mm | <0.5 W; Power supply 7.5V, 5 batteries | LCD display screen |
| 21 | ![]() |
Multi-parameter Portable Water Analyzer | LMS-PA100P | 220 mm × 120 mm × 100 mm | Rechargeable lithium battery with 220V to DC charging adapter | LCD display screen |
| 22 | ![]() |
Multi-parameter Touch-screen Online Analyzer | LMS-OA200T | 180 mm × 230 mm × 100 mm | AC power supply: 220 VAC | 7-inch touch screen |
Frequently Asked Questions
Q
What is the measurement range and accuracy of the LMS-ORP100 ORP sensor?
The LMS-ORP100 ORP sensor measures within a range of ±1000.0 mV with a resolution of 0.1 mV. It uses an ionic electrode method to deliver precise and stable readings, making it suitable for a wide range of water quality monitoring applications.
Q
What communication protocol does the ORP sensor support?
The LMS-ORP100 features an RS-485 output interface and supports the Modbus RTU protocol. This enables seamless integration with PLCs, data loggers, SCADA systems, and other industrial control platforms.
Q
Does the LMS-ORP100 support temperature compensation?
Yes. The sensor supports both automatic and manual temperature compensation, which helps maintain measurement accuracy under varying environmental and water temperature conditions.
Q
What are the power supply requirements for the ORP sensor?
The LMS-ORP100 operates on a supply voltage of 8–24 VDC, with 12 VDC recommended for optimal performance. Current consumption is approximately 55 mA at 12V. The sensor features an isolated power supply design for enhanced anti-interference capability.
Q
In which industries or environments can the LMS-ORP100 ORP sensor be used?
The LMS-ORP100 is suitable for a broad range of applications, including industrial wastewater treatment, aquaculture water quality management, environmental monitoring of rivers and lakes, drinking water treatment plants, scientific research laboratories, and recreational water facilities such as swimming pools and spas.
Q
Can the LMS-ORP100 be used alongside other water quality sensors in the same system?
Yes. The LMS-ORP100 is part of a comprehensive digital RS485 water quality sensor lineup that includes DO, pH, EC/TDS, turbidity, COD, residual chlorine, and many other sensors — all sharing the same RS-485 Modbus RTU interface. This makes it easy to build multi-parameter monitoring systems with a single communication bus.