The LMS-ORP100 ORP Sensor is a state-of-the-art digital electrode probe meticulously engineered for precise oxidation-reduction potential (ORP) measurements across diverse water quality applications. This high-precision sensor, designed by leading suppliers in China, employs an ionic electrode method that ensures a wide measurement range of ±1000.0 mV and outstanding accuracy of 0.1 mV, Constructed from durable polymer plastic, the compact and flat design of the sensor provides excellent resistance to breakage and is easy to maintain. It features both automatic and manual temperature compensation, facilitating accurate readings in varying conditions. The LMS-ORP100 supports RS485 communication with Modbus RTU protocol, making it a versatile choice for environmental monitoring, aquaculture, industrial processes, and laboratory research, As a product of a reliable factory in China, the LMS-ORP100 ORP Sensor is the perfect solution for professionals seeking dependable water quality monitoring tools

    Product Parameters

    Product Name ORP sensor
    Model LMS-ORP100
    Measurement method Lonic electrode
    Range ±1000.0mV
    Accuracy 0.1mV
    Power 9-24VDC(Recommend12 VDC)
    Voltage 8~24 VDC(55mA/ 12V)
    Material Polymer Plastic
    Size 31mm*140mm
    Output RS-485, MODBUS protocol

    Product Features

    ① High-Accuracy ORP Measurement
    Employs an advanced ionic electrode method to deliver precise and stable ORP readings up to ±1000.0 mV with a resolution of 0.1 mV.
    ② Robust and Compact Design
    Constructed with polymer plastic and a flat bubble structure, the sensor is durable, easy to clean, and resistant to damage.
    ③ Temperature Compensation Support
    Allows both automatic and manual temperature compensation for improved accuracy under varying environmental conditions.
    ④ Modbus RTU Communication
    Integrated RS485 interface supports the Modbus RTU protocol, enabling seamless integration with data loggers and control systems.
    ⑤ Anti-Interference and Stable Performance
    Features an isolated power supply design that ensures data stability and strong anti-interference capability in noisy electrical environments.
    X2
    X6

    Applications

    application
    Industrial Wastewater Treatment
    In chemical, electroplating, or printing and dyeing industries, the sensor monitors ORP during wastewater oxidation/reduction processes (e.g., removing heavy metals or organic pollutants). It helps operators confirm whether the reaction is complete (e.g., sufficient oxidant dosage) and ensures treated wastewater meets discharge standards, reducing environmental pollution.
    Aquaculture Water Quality Management
    In fish, shrimp, or shellfish farms (especially recirculating aquaculture systems), ORP reflects the level of organic matter and dissolved oxygen in water. Low ORP often indicates poor water quality and high disease risk. The sensor provides real-time data, allowing farmers to adjust aeration or add microbial agents timely, maintaining a healthy aquatic environment and improving breeding survival rates.
    Environmental Water Quality Monitoring
    For surface water (rivers, lakes, reservoirs) and groundwater, the sensor measures ORP to assess ecological health and pollution status. For example, abnormal ORP fluctuations may indicate sewage inflow; long-term data tracking can also evaluate the effectiveness of ecological restoration projects (e.g., lake eutrophication control), providing support for environmental protection departments.
    Drinking Water Safety Supervision
    In water treatment plants, the sensor is used in raw water pretreatment, disinfection (chlorine or ozone disinfection), and finished water storage. It ensures disinfection is thorough (sufficient oxidation to inactivate pathogens) while avoiding excessive disinfectant residues (which affect taste or produce harmful by-products). It also supports real-time monitoring of tap water pipelines, safeguarding end-user drinking water safety.
    Laboratory Scientific Research
    In environmental science, aquatic ecology, or water chemistry laboratories, the sensor provides high-precision ORP data for experiments. For example, it can analyze the oxidation behavior of pollutants, study the relationship between temperature/pH and ORP, or verify new water treatment technologies—supporting the development of scientific theories and practical applications.
    Swimming Pool & Recreational Water Maintenance
    In public swimming pools, water parks, or spas, ORP (typically 650-750mV) is a key indicator of disinfection effectiveness. The sensor monitors ORP continuously, enabling automatic adjustment of chlorine dosage. This reduces manual monitoring efforts and prevents bacterial growth (e.g., Legionella), ensuring a safe and hygienic water environment for users.
    X9
    X8

    Digital RS485 water quality sensors technical data

    Digital RS485 Water Quality Sensors Technical Data
    No. Picture Product Name Model Range Accuracy Resolution
    1 Digital RS4851 DO sensor LMS-DO10B 0-20mg/L, 0-60℃ ±0.1-0.3mg/L 0.01mg/L
    2 Digital RS4852 DO sensor LMS-DO10C 0-20mg/L, 0-60℃ ±0.3mg/L 0.01mg/l
    3 Digital RS4853 Trace DO sensor LMS-TDO100 0-2000ppb, 0-50℃ ±1ppb 1ppb
    4 Digital RS4854 PH sensor LMS-PH100 0-14pH ±0.02pH 0.01pH
    5 Digital RS4854 ORP sensor LMS-ORP100 ±1000.0 mV ±0.2 mV 0.1mV
    6 Digital RS4856 EC/TDS sensor LMS-TDS102 CT: 0-9999uS/cm; 0-100mS/cm;
    TDS: 0-10000ppm
    ±2.5%FS 1uS/cm,0.01mS/cm
    1ppm
    7 Digital RS4857 Salinity/EC/TDS sensor LMS-SAL104 Conductivity: 0.1-500 mS/cm TDS:0-60000ppm
    Salinity: 0-500.00ppt
    ±1.5%FS 1uS/cm,0.01mS/cm
    1ppm
    0.01ppt
    8 Digital RS4858 COD sensor LMS-COD100 COD:0.1-1500mg/L
    TOC:0.1-750mg/L
    BOD:0.1-900mg/L
    Turbidity: 0.1-4000NTU
    Temperature range: 0-50 ℃
    ±5% equiv.KHP
    Temperature: ± 0.5 ℃
    0.01mg/L equiv.KHP
    9 Digital RS4859 TSS sensor LMS-TSS100 0-50000mg/L/ 0-120000mg/L ±10%FS or 10 mg/L 0.1mg/L or 1mg/L
    10 Digital RS48510 Turbidity sensor LMS-TUR10L 0-100NTU ±10%FS or 0.3 NTU 0.01NTU
    11 Digital RS48510 Turbidity sensor LMS-TUR10H 0-3000NTU ±10%FS or 0.3 NTU 0.01NTU
    12 Digital RS48512 CO2 sensor LMS-CO2100 2000PPM/10000PPM/50000PPM ±5%FS 1ppm
    13 Digital RS48513 Ammonia Nitrogen sensor LMS-NH4100 0-1000 mg/L ±5%FS
    14 Digital RS48513 Ion Selective sensor LMS-ION100 0-1000 mg/L ±5%FS
    15 Digital RS48510 Oil in Water sensor LMS-OIL100 0-50 mg/L ; 0-5 mg/L ±3%FS 0.01ppm
    16 Digital RS48510 Chlorophyll sensor LMS-CHL100 0-500ug/L ±3%FS 0.1ug/L
    17 Digital RS48510 Blue-Green Algae sensor LMS-BGA100 0-2000,000 cells/ml ±3%FS
    18 Digital RS48518 Residual Chlorine sensor LMS-HCLO100 0 - 20.00 ppm ±5%FS 0.001 / 0.01ppm
    19 Digital RS48519 Marine Current sensor LMS-Current100 Temperature:-3℃ - 45℃
    Velocity of flow:0-500 cm/s
    Flow direction:0-359.9°
    ±0.05℃
    ±1 cm/s or ±2%
    ±2°
    Temperature: 0.001℃
    Velocity of flow:0.1 cm/s
    Flow direction:0.1°
    Water Quality Analyzer Equipment
    No. Picture Product Name Model Size / Power Display Output
    20 Digital RS48520 Protable DO Analyzer LMS-PA100 100mm*204mm
    < 0.5 W Power supply 7.5V, 5 batteries
    LCD display screen
    21 Digital RS48521 Multi-parameter Protable Water Analyzer LMS-PA100P 220mm*120mm*100mm
    Rechargeable lithium battery with 220v to dc charging adapter
    LCD display screen
    22 Digital RS48522 Multi-parameter Touch-screen Online Analyzer LMS-OA200T 180mmx230mmx100mm
    AC power supply: 220 VAC
    7-inch touch screen

    Frequently Asked Questions (FAQ)

    Q What is the measurement range and accuracy of the LMS-ORP100 sensor?
    The LMS-ORP100 sensor features a measurement range of ±1000.0 mV with a resolution of 0.1 mV and high accuracy, making it ideal for precise industrial and environmental applications.
    Q Does this ORP sensor support automatic temperature compensation?
    Yes, the sensor supports both automatic and manual temperature compensation to ensure accurate and stable readings under varying environmental conditions.
    Q What communication protocol does the LMS-ORP100 use?
    It features an integrated RS485 communication interface and supports the standard Modbus RTU protocol, allowing for seamless integration with data loggers, PLCs, and control systems.
    Q What materials are used in the construction of the sensor?
    The sensor body is constructed with high-quality polymer plastic and features a flat bubble structure, ensuring durability, easy cleaning, and resistance to physical damage.
    Q What are the power requirements for this ORP sensor?
    The sensor operates on a wide input voltage range of 9-24VDC (8~24 VDC, 55mA/12V), with 12VDC being the recommended supply voltage for optimal performance.