This advanced chlorophyll sensor, designed by leading suppliers in China, offers precise and reliable real-time measurements of chlorophyll concentrations in aquatic environments. Utilizing state-of-the-art modulation and coherent detection technology, it enhances sensitivity while effectively resisting external interference. As a factory-manufactured product, it seamlessly integrates into online monitoring systems without the need for chemical reagents, providing an eco-friendly, low-maintenance solution that reduces both operational costs and environmental impact, Featuring an automatic cleaning mechanism to prevent biofouling, this sensor ensures long-term stability even in challenging water conditions. Its robust 316L stainless steel casing (48mm×125mm) supports the RS-485 MODBUS protocol, facilitating easy connectivity to industrial, municipal, and research platforms. Perfect for monitoring algal blooms, evaluating water eutrophication, and preserving ecological balance in lakes, rivers, reservoirs, and aquaculture systems, this high-precision chlorophyll sensor stands as a premier choice for those seeking quality solutions from reliable suppliers in China

    Product Parameters
    Product Name Chlorophyll Sensor
    Measurement Method Fluorescent
    Range 0–500 ug/L  |  Temperature: 0–50℃
    Accuracy ±3% F.S.  |  Temperature: ±0.5℃
    Power 9–24 VDC (Recommended: 12 VDC)
    Size 48mm × 125mm
    Material 316L Stainless Steel
    Output RS-485, MODBUS Protocol
    Product Features
    • Modulation & Coherent Detection Technology
      Utilizes advanced optical modulation and signal processing to enhance sensitivity and eliminate ambient light interference, ensuring reliable measurements in dynamic water conditions.
    • Reagent-Free & Pollution-Free Operation
      No chemical reagents required, reducing operational costs and environmental impact while aligning with sustainable water management practices.
    • 24/7 Online Monitoring
      Supports continuous, real-time data collection for early detection of algal blooms, eutrophication trends, and ecosystem imbalances.
    • Integrated Self-Cleaning System
      Equipped with an automatic wiper to prevent biofilm buildup and sensor fouling, ensuring consistent accuracy and minimal manual maintenance.
    • Robust Design for Harsh Environments
      Encased in corrosion-resistant 316L stainless steel, the sensor withstands prolonged submersion and extreme temperatures (0–50°C), ideal for marine and industrial applications.
    Application
    • 1
      Environmental Water Quality Protection
      Monitor chlorophyll-a levels in lakes, rivers, and reservoirs to assess algal biomass and prevent harmful algal blooms (HABs).
    • 2
      Drinking Water Safety
      Deploy at water treatment facilities to track chlorophyll concentrations and mitigate risks of toxin contamination in potable supplies.
    • 3
      Aquaculture Management
      Optimize water conditions for fish and shellfish farming by monitoring algal growth, preventing oxygen depletion and fish mortality.
    • 4
      Coastal and Marine Research
      Study phytoplankton dynamics in coastal ecosystems to support climate research and marine conservation efforts.
    • 5
      Industrial Effluent Monitoring
      Integrate into wastewater treatment systems to ensure compliance with environmental regulations and reduce ecological impacts.
    application
    Digital RS485 Water Quality Sensors Technical Data
    Parameter Model Range Accuracy
    DO Sensor LMS-DO10B 0–20 mg/L, 0–60℃ ±0.1–0.3 mg/L
    DO Sensor LMS-DO10C 0–20 mg/L, 0–60℃ ±0.3 mg/L
    Trace DO Sensor LMS-TDO100 0–2000 ppb, 0–50℃ ±1 ppb
    PH Sensor LMS-PH100 0–14 pH ±0.02 pH
    ORP Sensor LMS-ORP100 ±1000.0 mV ±0.2 mV
    EC/TDS Sensor LMS-TDS102 CT: 0–9999 uS/cm; 0–100 mS/cm
    TDS: 0–10000 ppm
    ±2.5% FS
    Salinity/EC/TDS Sensor LMS-SAL104 Conductivity: 0.1–500 mS/cm
    TDS: 0–60000 ppm
    Salinity: 0–500.00 ppt
    ±1.5% FS
    COD Sensor LMS-COD100 COD: 0.1–1500 mg/L
    TOC: 0.1–750 mg/L
    BOD: 0.1–900 mg/L
    Turbidity: 0.1–4000 NTU
    Temperature: 0–50℃
    ±5% equiv. KHP
    Temperature: ±0.5℃
    TSS Sensor LMS-TSS100 0–50000 mg/L / 0–120000 mg/L ±10% FS or 10 mg/L
    Turbidity Sensor LMS-TUR10L 0–100 NTU ±10% FS or 0.3 NTU
    Turbidity Sensor LMS-TUR10H 0–3000 NTU ±10% FS or 0.3 NTU
    CO2 Sensor LMS-CO2100 2000 PPM / 10000 PPM / 50000 PPM ±5% FS
    Ammonia Nitrogen Sensor LMS-NH4100 0–1000 mg/L ±5% FS
    Ion Selective Sensor LMS-ION100 0–1000 mg/L ±5% FS
    Oil in Water Sensor LMS-OIL100 0–50 mg/L; 0–5 mg/L ±3% FS
    Chlorophyll Sensor LMS-CHL100 0–500 ug/L ±3% FS
    Blue-Green Algae Sensor LMS-BGA100 0–2,000,000 cells/ml ±3% FS
    Residual Chlorine Sensor LMS-HCLO100 0–20.00 ppm ±5% FS
    Marine Current Sensor LMS-Current100 Temperature: -3℃ – 45℃
    Velocity of Flow: 0–500 cm/s
    Flow Direction: 0–359.9°
    ±0.05℃
    ±1 cm/s or ±2%
    ±2°
    more products
    Frequently Asked Questions (FAQ)
    QWhat measurement method does the Chlorophyll Sensor use?
    AThe chlorophyll sensor uses a fluorescent measurement method. It emits a specific wavelength of light to excite chlorophyll molecules in the water, then measures the fluorescence emitted, providing accurate and real-time chlorophyll concentration data.
    QWhat is the measurement range of the Chlorophyll Sensor (LMS-CHL100)?
    AThe sensor measures chlorophyll concentrations in the range of 0–500 ug/L, with an operating temperature range of 0–50℃ and an accuracy of ±3% F.S., making it suitable for a wide variety of freshwater and marine environments.
    QDoes the Chlorophyll Sensor require chemical reagents for operation?
    ANo. The sensor is completely reagent-free, which means no chemical consumables are needed. This significantly reduces operating costs, eliminates chemical waste, and makes it an environmentally friendly solution for continuous water quality monitoring.
    QHow does the self-cleaning system work on this sensor?
    AThe sensor is equipped with an integrated automatic wiper mechanism that periodically cleans the optical window to prevent biofilm buildup and biofouling. This ensures measurement accuracy is maintained over extended deployment periods with minimal manual intervention.
    QWhat communication protocol does the Chlorophyll Sensor support?
    AThe sensor outputs data via RS-485 using the MODBUS protocol, which allows easy integration with PLCs, data loggers, SCADA systems, and other industrial monitoring platforms for seamless data acquisition and remote management.
    QWhat are the typical applications for the Chlorophyll Sensor?
    AThe sensor is widely used in environmental water quality monitoring (lakes, rivers, reservoirs), drinking water treatment facilities, aquaculture management, coastal and marine research, and industrial effluent monitoring. It is especially valuable for detecting and preventing harmful algal blooms (HABs) and tracking eutrophication trends.

    Leave Your Message

    AI Helps Write