High-Precision UV Fluorescent Chlorophyll Sensor from China Suppliers - Eco-Friendly Solutions for Aquatic Monitoring Factory

Introducing our high-precision chlorophyll sensor, designed specifically for aquatic environments in China. This innovative sensor provides reliable, real-time measurements of chlorophyll concentrations, leveraging advanced modulation and coherent detection technology for enhanced sensitivity and reduced external interference. As a leading factory and supplier, we ensure that our product integrates seamlessly into online monitoring systems, operating without the need for chemical reagents. This eco-friendly and low-maintenance solution significantly cuts operational costs and minimizes environmental impact, Our chlorophyll sensor is equipped with an automatic cleaning mechanism to prevent biofouling, ensuring long-term stability even in challenging water conditions. Encased in a robust 316L stainless steel housing (48mm×125mm), it supports the RS-485 MODBUS protocol, making it easy to connect to various industrial, municipal, and research platforms. Perfect for monitoring algal blooms, assessing water eutrophication, and maintaining ecological balance in lakes, rivers, reservoirs, and aquaculture systems, this sensor is a must-have for conscious water management in China. Choose our factory for a reliable and efficient chlorophyll sensing solution

    Product Parameters
    Product Name Chlorophyll Sensor
    Measurement method Fluorescent
    Range 0-500ug/L; Temperature: 0-50℃
    Accuracy ±3%F.S. Temperature: ±0.5℃
    Power 9-24VDC(Recommend 12 VDC)
    Size 48mm × 125mm
    Material 316L Stainless Steel
    Output RS-485, MODBUS protocol
    Product Features
    • Modulation & Coherent Detection Technology Utilizes advanced optical modulation and signal processing to enhance sensitivity and eliminate ambient light interference, ensuring reliable measurements in dynamic water conditions.
    • Reagent-Free & Pollution-Free Operation No chemical reagents required, reducing operational costs and environmental impact while aligning with sustainable water management practices.
    • 24/7 Online Monitoring Supports continuous, real-time data collection for early detection of algal blooms, eutrophication trends, and ecosystem imbalances.
    • Integrated Self-Cleaning System Equipped with an automatic wiper to prevent biofilm buildup and sensor fouling, ensuring consistent accuracy and minimal manual maintenance.
    • Robust Design for Harsh Environments Encased in corrosion-resistant 316L stainless steel, the sensor withstands prolonged submersion and extreme temperatures (0-50°C), ideal for marine and industrial applications.
    Application
    • 1
      Environmental Water Quality Protection Monitor chlorophyll-a levels in lakes, rivers, and reservoirs to assess algal biomass and prevent harmful algal blooms (HABs).
    • 2
      Drinking Water Safety Deploy at water treatment facilities to track chlorophyll concentrations and mitigate risks of toxin contamination in potable supplies.
    • 3
      Aquaculture Management Optimize water conditions for fish and shellfish farming by monitoring algal growth, preventing oxygen depletion and fish mortality.
    • 4
      Coastal and Marine Research Study phytoplankton dynamics in coastal ecosystems to support climate research and marine conservation efforts.
    • 5
      Industrial Effluent Monitoring Integrate into wastewater treatment systems to ensure compliance with environmental regulations and reduce ecological impacts.
    application
    Digital RS485 Water Quality Sensors Technical Data
    Parameter Model Range Accuracy
    DO sensor LMS-DO10B 0-20mg/L, 0-60℃ ±0.1-0.3mg/L
    DO sensor LMS-DO10C 0-20mg/L, 0-60℃ ±0.3mg/L
    Trace DO sensor LMS-TDO100 0-2000ppb, 0-50℃ ±1ppb
    PH sensor LMS-PH100 0-14pH ±0.02pH
    ORP sensor LMS-ORP100 ±1000.0 mV ±0.2 mV
    EC/TDS sensor LMS-TDS102 CT: 0-9999uS/cm; 0-100mS/cm;
    TDS: 0-10000ppm
    ±2.5%FS
    Salinity/EC/TDS sensor LMS-SAL104 Conductivity: 0.1-500 mS/cm
    TDS: 0-60000ppm
    Salinity: 0-500.00ppt
    ±1.5%FS
    COD sensor LMS-COD100 COD: 0.1-1500mg/L
    TOC: 0.1-750mg/L
    BOD: 0.1-900mg/L
    Turbidity: 0.1-4000NTU
    Temperature: 0-50℃
    ±5% equiv.KHP
    Temperature: ±0.5℃
    TSS sensor LMS-TSS100 0-50000mg/L / 0-120000mg/L ±10%FS or 10 mg/L
    Turbidity sensor LMS-TUR10L 0-100NTU ±10%FS or 0.3 NTU
    Turbidity sensor LMS-TUR10H 0-3000NTU ±10%FS or 0.3 NTU
    CO2 sensor LMS-CO2100 2000PPM / 10000PPM / 50000PPM ±5%FS
    Ammonia Nitrogen sensor LMS-NH4100 0-1000 mg/L ±5%FS
    Ion Selective sensor LMS-ION100 0-1000 mg/L ±5%FS
    Oil in Water sensor LMS-OIL100 0-50 mg/L; 0-5 mg/L ±3%FS
    Chlorophyll sensor LMS-CHL100 0-500ug/L ±3%FS
    Blue-Green Algae sensor LMS-BGA100 0-2000,000 cells/ml ±3%FS
    Residual Chlorine sensor LMS-HCLO100 0 - 20.00 ppm ±5%FS
    Marine Current sensor LMS-Current100 Temperature: -3℃ - 45℃
    Velocity of flow: 0-500 cm/s
    Flow direction: 0-359.9°
    ±0.05℃
    ±1 cm/s or ±2%
    ±2°
    more products
    Frequently Asked Questions (FAQ)
    Q
    What measurement principle does the Chlorophyll Sensor use?
    The Chlorophyll Sensor uses fluorescence-based detection combined with optical modulation and coherent signal processing technology. This method excites chlorophyll molecules in the water and measures the emitted fluorescence, providing accurate and interference-free readings even in dynamic or turbid water environments.
    Q
    What is the measurement range of the LMS-CHL100 Chlorophyll Sensor?
    The LMS-CHL100 has a chlorophyll measurement range of 0–500 µg/L with an accuracy of ±3% F.S. It also measures water temperature in the range of 0–50°C with an accuracy of ±0.5°C, making it suitable for a wide variety of freshwater and marine monitoring scenarios.
    Q
    Does the sensor require chemical reagents for operation?
    No. The Chlorophyll Sensor is completely reagent-free. It relies solely on optical fluorescence detection, which eliminates the need for any chemical reagents. This not only reduces ongoing operational costs but also minimizes environmental impact, aligning with sustainable water quality monitoring practices.
    Q
    How does the self-cleaning system work and why is it important?
    The sensor is equipped with an integrated automatic wiper that periodically cleans the optical window to remove biofilm, algae, and sediment buildup. This self-cleaning mechanism ensures long-term measurement stability and accuracy, significantly reducing the frequency of manual maintenance — especially important for remote or continuously deployed monitoring installations.
    Q
    What communication protocol does the sensor support, and how can it be integrated into a monitoring system?
    The Chlorophyll Sensor outputs data via RS-485 using the standard MODBUS protocol. This makes it highly compatible with a wide range of data loggers, PLCs, SCADA systems, and IoT water quality monitoring platforms. It operates on a 9–24VDC power supply (12VDC recommended), allowing flexible deployment in both fixed and portable setups.
    Q
    In what environments and applications can the Chlorophyll Sensor be deployed?
    The sensor is designed for versatile deployment across multiple environments. Its 316L stainless steel housing ensures durability in corrosive and high-pressure underwater conditions. It is widely used in lakes, rivers, reservoirs, coastal marine zones, aquaculture facilities, drinking water treatment plants, and industrial wastewater systems — anywhere continuous and reliable chlorophyll monitoring is needed.