- Multi-parameter Water Analyzer
- Single-Parameter Water Aalyzer
- DO Sensor
- Trace DO Sensor
- CO₂ Sensor
- COD Sensor
- EC TDS Sensor
- Salinity EC TDS Sensor
- TSS Sensor
- Turbidity Sensor
- PH Sensor
- ORP
- Ion Selective Sensor
- Ammonia Nitrogen Sensor
- Oil in Water Sensor
- Blue-Green Algae Sensor
- Chlorophyll Sensor
- Residual Chlorine Sensor
- Marine Current Sensor
0102030405
High-Precision UV Fluorescent Chlorophyll Sensor from China Suppliers - Eco-Friendly Solutions for Aquatic Monitoring Factory
Product Parameters
| Product Name | Chlorophyll Sensor |
| Measurement method | Fluorescent |
| Range | 0-500ug/L; Temperature: 0-50℃ |
| Accuracy | ±3%F.S. Temperature: ±0.5℃ |
| Power | 9-24VDC(Recommend 12 VDC) |
| Size | 48mm × 125mm |
| Material | 316L Stainless Steel |
| Output | RS-485, MODBUS protocol |
Product Features
-
①Modulation & Coherent Detection Technology Utilizes advanced optical modulation and signal processing to enhance sensitivity and eliminate ambient light interference, ensuring reliable measurements in dynamic water conditions.
-
②Reagent-Free & Pollution-Free Operation No chemical reagents required, reducing operational costs and environmental impact while aligning with sustainable water management practices.
-
③24/7 Online Monitoring Supports continuous, real-time data collection for early detection of algal blooms, eutrophication trends, and ecosystem imbalances.
-
④Integrated Self-Cleaning System Equipped with an automatic wiper to prevent biofilm buildup and sensor fouling, ensuring consistent accuracy and minimal manual maintenance.
-
⑤Robust Design for Harsh Environments Encased in corrosion-resistant 316L stainless steel, the sensor withstands prolonged submersion and extreme temperatures (0-50°C), ideal for marine and industrial applications.
Application
-
1Environmental Water Quality Protection Monitor chlorophyll-a levels in lakes, rivers, and reservoirs to assess algal biomass and prevent harmful algal blooms (HABs).
-
2Drinking Water Safety Deploy at water treatment facilities to track chlorophyll concentrations and mitigate risks of toxin contamination in potable supplies.
-
3Aquaculture Management Optimize water conditions for fish and shellfish farming by monitoring algal growth, preventing oxygen depletion and fish mortality.
-
4Coastal and Marine Research Study phytoplankton dynamics in coastal ecosystems to support climate research and marine conservation efforts.
-
5Industrial Effluent Monitoring Integrate into wastewater treatment systems to ensure compliance with environmental regulations and reduce ecological impacts.
Digital RS485 Water Quality Sensors Technical Data
| Parameter | Model | Range | Accuracy |
| DO sensor | LMS-DO10B | 0-20mg/L, 0-60℃ | ±0.1-0.3mg/L |
| DO sensor | LMS-DO10C | 0-20mg/L, 0-60℃ | ±0.3mg/L |
| Trace DO sensor | LMS-TDO100 | 0-2000ppb, 0-50℃ | ±1ppb |
| PH sensor | LMS-PH100 | 0-14pH | ±0.02pH |
| ORP sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV |
| EC/TDS sensor | LMS-TDS102 | CT: 0-9999uS/cm; 0-100mS/cm; TDS: 0-10000ppm |
±2.5%FS |
| Salinity/EC/TDS sensor | LMS-SAL104 | Conductivity: 0.1-500 mS/cm TDS: 0-60000ppm Salinity: 0-500.00ppt |
±1.5%FS |
| COD sensor | LMS-COD100 | COD: 0.1-1500mg/L TOC: 0.1-750mg/L BOD: 0.1-900mg/L Turbidity: 0.1-4000NTU Temperature: 0-50℃ |
±5% equiv.KHP Temperature: ±0.5℃ |
| TSS sensor | LMS-TSS100 | 0-50000mg/L / 0-120000mg/L | ±10%FS or 10 mg/L |
| Turbidity sensor | LMS-TUR10L | 0-100NTU | ±10%FS or 0.3 NTU |
| Turbidity sensor | LMS-TUR10H | 0-3000NTU | ±10%FS or 0.3 NTU |
| CO2 sensor | LMS-CO2100 | 2000PPM / 10000PPM / 50000PPM | ±5%FS |
| Ammonia Nitrogen sensor | LMS-NH4100 | 0-1000 mg/L | ±5%FS |
| Ion Selective sensor | LMS-ION100 | 0-1000 mg/L | ±5%FS |
| Oil in Water sensor | LMS-OIL100 | 0-50 mg/L; 0-5 mg/L | ±3%FS |
| Chlorophyll sensor | LMS-CHL100 | 0-500ug/L | ±3%FS |
| Blue-Green Algae sensor | LMS-BGA100 | 0-2000,000 cells/ml | ±3%FS |
| Residual Chlorine sensor | LMS-HCLO100 | 0 - 20.00 ppm | ±5%FS |
| Marine Current sensor | LMS-Current100 | Temperature: -3℃ - 45℃ Velocity of flow: 0-500 cm/s Flow direction: 0-359.9° |
±0.05℃ ±1 cm/s or ±2% ±2° |
❓
Frequently Asked Questions (FAQ)
Q
What measurement principle does the Chlorophyll Sensor use?
The Chlorophyll Sensor uses fluorescence-based detection combined with optical modulation and coherent signal processing technology. This method excites chlorophyll molecules in the water and measures the emitted fluorescence, providing accurate and interference-free readings even in dynamic or turbid water environments.
Q
What is the measurement range of the LMS-CHL100 Chlorophyll Sensor?
The LMS-CHL100 has a chlorophyll measurement range of 0–500 µg/L with an accuracy of ±3% F.S. It also measures water temperature in the range of 0–50°C with an accuracy of ±0.5°C, making it suitable for a wide variety of freshwater and marine monitoring scenarios.
Q
Does the sensor require chemical reagents for operation?
No. The Chlorophyll Sensor is completely reagent-free. It relies solely on optical fluorescence detection, which eliminates the need for any chemical reagents. This not only reduces ongoing operational costs but also minimizes environmental impact, aligning with sustainable water quality monitoring practices.
Q
How does the self-cleaning system work and why is it important?
The sensor is equipped with an integrated automatic wiper that periodically cleans the optical window to remove biofilm, algae, and sediment buildup. This self-cleaning mechanism ensures long-term measurement stability and accuracy, significantly reducing the frequency of manual maintenance — especially important for remote or continuously deployed monitoring installations.
Q
What communication protocol does the sensor support, and how can it be integrated into a monitoring system?
The Chlorophyll Sensor outputs data via RS-485 using the standard MODBUS protocol. This makes it highly compatible with a wide range of data loggers, PLCs, SCADA systems, and IoT water quality monitoring platforms. It operates on a 9–24VDC power supply (12VDC recommended), allowing flexible deployment in both fixed and portable setups.
Q
In what environments and applications can the Chlorophyll Sensor be deployed?
The sensor is designed for versatile deployment across multiple environments. Its 316L stainless steel housing ensures durability in corrosive and high-pressure underwater conditions. It is widely used in lakes, rivers, reservoirs, coastal marine zones, aquaculture facilities, drinking water treatment plants, and industrial wastewater systems — anywhere continuous and reliable chlorophyll monitoring is needed.