Product Parameters
| Product Name | Portable Multi-parameter Water Quality Analyzer ( CO₂+ Ion ) |
| Model | LMS-PA100P |
| Range |
ION: 0 ~ 1000 mg/L CO₂: 2000/10000/50000 PPM (other ranges available) |
| Accuracy | ±5%F.S. |
| Power |
Ion Sensors: DC 9~24V; CO₂: DC5V Analyzer: Rechargeable lithium battery with 220v to dc charging adapter |
| Material | Polymer Plastic |
| Size | 220mm*120mm*100mm |
| Temperature |
Working Conditions 0-50℃ Storage Temperature -40~85℃ |
| Cable length | 5m, can be extended according to user need |
Product Features
①
Multi-Parameter Integrated Detection
Supports 21-parameter measurement, integrating Ion Selective Detection (23 ions optional, e.g., NH₄⁺, NO₃⁻, K⁺, Ca²⁺) and dissolved CO₂ detection based on the NDIR principle, enabling simultaneous capture of multiple critical water quality indicators to meet comprehensive monitoring needs.
②
Advanced Sensing Technology
The ion sensor adopts the ionic electrode method with a power isolation design for strong data stability; the CO₂ sensor is equipped with a patented optical cavity and dual-channel detector for spatial dual-path reference compensation. Both ensure high detection accuracy (Ion: ±5%F.S., CO₂: ≤±5%F.S.).
③
Easy Integration & Maintenance
Environmentally friendly design, easily integrable into existing water quality monitoring systems. The ion sensor supports direct immersion installation; the CO₂ sensor is equipped with a detachable protective cover and convection diffusion ventilation design to accelerate gas diffusion and facilitate daily maintenance.
④
Multiple Output Modes + Robust Structure
The ion sensor outputs via RS485 (MODBUS protocol); the CO₂ sensor supports multiple output methods such as UART, IIC, and analog voltage. Both are made of polymer plastics with a waterproof design, suitable for long-term use in multiple environments such as seawater and freshwater.
⑤
Flexible Calibration + User-Friendly Operation
The ion sensor supports custom standard solution calibration (forward/reverse curves); the CO₂ sensor has a manual calibration function (MCDL pin) for on-site zero adjustment, with user-friendly operation to lower the usage threshold.
⑥
Flexible Expansion + Plug-and-Play
In addition to the core parameters of ions and CO₂, other Luminsens series sensors can be freely expanded later without complex modification, achieving plug-and-play to adapt to the dynamic upgrade of monitoring needs.
Application
🐟 Aquaculture Industry (Seawater/Freshwater)
For various aquaculture scenarios such as fish, shrimp, and shellfish, it monitors harmful ions (e.g., NH₄⁺, NO₃⁻), nutrient ions (e.g., K⁺, Ca²⁺), and dissolved CO₂ concentration in water bodies in real time, precisely regulating the water quality environment to ensure the healthy growth of aquatic organisms. Sensors can be expanded later as needed to adapt to the expansion of aquaculture scale or the addition of new monitoring parameters.
💧 Comprehensive Water Quality Monitoring Projects
Applicable to various water bodies such as surface water, groundwater, domestic sewage, and industrial wastewater, it simultaneously detects ion composition (aiding pollution source tracing and water quality category determination) and dissolved CO₂ content (reflecting water body acid-base balance and ecological metabolic status), providing comprehensive data support for water quality compliance assessment and pollution control effect verification, and can be flexibly integrated into existing monitoring systems.
🏭 Industrial Water Treatment & Environmental Quality Control
Suitable for water treatment scenarios in industries such as chemical, electronics, and food processing, as well as water quality monitoring in sewage treatment plants. It controls water salinity and pollutant ion content through ion sensors, monitors acid-base adjustment-related parameters during water treatment via CO₂ sensors, and supports the expansion of other functional sensors to build a customized water quality control system to ensure discharge compliance.
🥤 Food and Beverage Production Quality Control
Focuses on the production process of carbonated beverages (e.g., Coke, Sprite, etc.), accurately measures the dissolved CO₂ content in products to ensure consistent carbonation taste and stable product quality; meanwhile, it can monitor the mineral ion content in beverages through ion sensors to assist in controlling formula compliance, adapting to the online monitoring needs of production lines.
🔬 Scientific Research & Ecological Environment Monitoring Projects
Meets the needs of scenarios such as field research and marine/inland water ecological surveys, focusing on monitoring core ion and CO₂ parameters to support ecological environment change research. With plug-and-play expansion capability, other sensors can be flexibly added according to research directions, helping to ensure the completeness and flexibility of data collection.
More Products
| Digital RS485 Water Quality Sensors Technical Data | ||||||
| No. | Picture | Product Name | Model | Range | Accuracy | Resolution |
| 1 | ![]() |
DO sensor | LMS-DO10B | 0-20mg/L, 0-60℃ | ±0.1-0.3mg/L | 0.01mg/L |
| 2 | ![]() |
DO sensor | LMS-DO10C | 0-20mg/L, 0-60℃ | ±0.3mg/L | 0.01mg/l |
| 3 | ![]() |
Trace DO sensor | LMS-TDO100 | 0-2000ppb, 0-50℃ | ±1ppb | 1ppb |
| 4 | ![]() |
PH sensor | LMS-PH100 | 0-14pH | ±0.02pH | 0.01pH |
| 5 | ![]() |
ORP sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV | 0.1mV |
| 6 | ![]() |
EC/TDS sensor | LMS-TDS102 | CT: 0-9999uS/cm; 0-100mS/cm; TDS: 0-10000ppm | ±2.5%FS | 1uS/cm, 0.01mS/cm, 1ppm |
| 7 | ![]() |
Salinity/EC/TDS sensor | LMS-SAL104 | Conductivity: 0.1-500 mS/cm; TDS: 0-60000ppm; Salinity: 0-500.00ppt | ±1.5%FS | 1uS/cm, 0.01mS/cm, 1ppm, 0.01ppt |
| 8 | ![]() |
COD sensor | LMS-COD100 | COD: 0.1-1500mg/L; TOC: 0.1-750mg/L; BOD: 0.1-900mg/L; Turbidity: 0.1-4000NTU; Temp: 0-50℃ | ±5% equiv.KHP; Temp: ±0.5℃ | 0.01mg/L equiv.KHP |
| 9 | ![]() |
TSS sensor | LMS-TSS100 | 0-50000mg/L / 0-120000mg/L | ±10%FS or 10 mg/L | 0.1mg/L or 1mg/L |
| 10 | ![]() |
Turbidity sensor | LMS-TUR10L | 0-100NTU | ±10%FS or 0.3 NTU | 0.01NTU |
| 11 | ![]() |
Turbidity sensor | LMS-TUR10H | 0-3000NTU | ±10%FS or 0.3 NTU | 0.01NTU |
| 12 | ![]() |
CO2 sensor | LMS-CO2100 | 2000PPM / 10000PPM / 50000PPM | ±5%FS | 1ppm |
| 13 | ![]() |
Ammonia Nitrogen sensor | LMS-NH4100 | 0-1000 mg/L | ±5%FS | — |
| 14 | ![]() |
Ion Selective sensor | LMS-ION100 | 0-1000 mg/L | ±5%FS | — |
| 15 | ![]() |
Oil in Water sensor | LMS-OIL100 | 0-50 mg/L; 0-5 mg/L | ±3%FS | 0.01ppm |
| 16 | ![]() |
Chlorophyll sensor | LMS-CHL100 | 0-500ug/L | ±3%FS | 0.1ug/L |
| 17 | ![]() |
Blue-Green Algae sensor | LMS-BGA100 | 0-2,000,000 cells/ml | ±3%FS | — |
| 18 | ![]() |
Residual Chlorine sensor | LMS-HCLO100 | 0 - 20.00 ppm | ±5%FS | 0.001 / 0.01ppm |
| 19 | ![]() |
Marine Current sensor | LMS-Current100 | Temp: -3℃~45℃; Flow: 0-500 cm/s; Direction: 0-359.9° | ±0.05℃; ±1 cm/s or ±2%; ±2° | 0.001℃; 0.1 cm/s; 0.1° |
| Water Quality Analyzer Equipment | ||||||
| No. | Picture | Product Name | Model | Size | Power | Display Output |
| 20 | ![]() |
Portable DO Analyzer | LMS-PA100 | 100mm*204mm | <0.5W; 7.5V, 5 batteries | LCD display screen |
| 21 | ![]() |
Multi-parameter Portable Water Analyzer | LMS-PA100P | 220mm*120mm*100mm | Rechargeable lithium battery with 220v to dc charging adapter | LCD display screen |
| 22 | ![]() |
Multi-parameter Touch-screen Online Analyzer | LMS-OA200T | 180mm×230mm×100mm | AC power supply: 220 VAC | 7-inch touch screen |
Frequently Asked Questions (FAQ)
Q What parameters can the LMS-PA100P Portable Multi-parameter Water Quality Analyzer measure?
The LMS-PA100P supports up to 21-parameter measurement. It integrates Ion Selective Detection (with 23 ions optional, including NH₄⁺, NO₃⁻, K⁺, Ca²⁺, etc.) and dissolved CO₂ detection based on the NDIR principle. Additional Luminsens series sensors can also be expanded later for broader monitoring needs.
Q What is the CO₂ detection range of the LMS-PA100P?
The CO₂ sensor supports multiple ranges: 2000 PPM, 10000 PPM, and 50000 PPM. Other custom ranges are also available upon request to suit specific application requirements.
Q How is the LMS-PA100P powered, and how long does the battery last?
The analyzer is powered by a built-in rechargeable lithium battery with a 220V to DC charging adapter included. The ion sensors operate at DC 9~24V and the CO₂ sensor at DC 5V. Battery life varies depending on usage conditions and the number of connected sensors.
Q Is the LMS-PA100P suitable for use in both seawater and freshwater environments?
Yes. Both the ion sensor and CO₂ sensor are constructed from polymer plastics with a waterproof design, making the LMS-PA100P suitable for long-term deployment in various environments including seawater, freshwater, industrial wastewater, and more.
Q How do I calibrate the ion sensor and CO₂ sensor on the LMS-PA100P?
The ion sensor supports custom standard solution calibration with both forward and reverse curve options. The CO₂ sensor features a manual calibration function via the MCDL pin for on-site zero adjustment. Both calibration processes are designed to be user-friendly and straightforward, lowering the technical threshold for field operators.
Q Can the LMS-PA100P be integrated into an existing water quality monitoring system?
Absolutely. The ion sensor communicates via RS485 (MODBUS protocol), while the CO₂ sensor supports UART, IIC, and analog voltage output modes. This multi-output flexibility allows the LMS-PA100P to be seamlessly integrated into most existing water quality monitoring and data acquisition systems without complex modifications.