- Multi-parameter Water Analyzer
- Single-Parameter Water Aalyzer
- DO Sensor
- Trace DO Sensor
- CO₂ Sensor
- COD Sensor
- EC TDS Sensor
- Salinity EC TDS Sensor
- TSS Sensor
- Turbidity Sensor
- PH Sensor
- ORP
- Ion Selective Sensor
- Ammonia Nitrogen Sensor
- Oil in Water Sensor
- Blue-Green Algae Sensor
- Chlorophyll Sensor
- Residual Chlorine Sensor
- Marine Current Sensor
0102030405
Portable Multi-Parameter Water Quality Analyzer - DO, pH, Salinity, Turbidity | China Suppliers & Factory
Product Parameters
| Product Name | Portable Multi-parameter Water Quality Analyzer |
| Range | DO: 0–20 mg/L or 0–200% saturation PH: 0–14 pH CT/EC: 0–500 mS/cm SAL: 0–500.00 ppt TUR: 0–3000 NTU |
| Accuracy | DO: ±1~3% PH: ±0.02 CT/EC: 0–9999 uS/cm; 10.00–70.00 mS/cm SAL: <1.5% F.S. or 1% of reading, whichever is smaller TUR: Less than ±10% of measured value or 0.3 NTU, whichever is greater |
| Power | Sensors: DC 12~24V Analyzer: Rechargeable lithium battery with 220V to DC charging adapter |
| Material | Polymer Plastic |
| Size | 220 mm × 120 mm × 100 mm |
| Temperature | Working Conditions: 0–50℃ Storage Temperature: -40~85℃ |
| Cable Length | 5 m, can be extended according to user need |
| Sensor Interface Supports | RS-485, MODBUS protocol |
Product Features
-
🔧
① Meet Your Customized Needs: Customizable measurement parameters and sensor probes, including DO/PH/SAL/CT/TUR/Temperature, etc.
-
💡
② Cost-Effective: Multifunctional in one device. It has a universal platform where Luminsens sensors can be freely inserted and automatically recognized.
-
⚙️
③ Easy Maintenance and Calibration: All calibration parameters are stored in individual sensors. Supported by RS485 with Modbus protocol.
-
🛡️
④ Reliable Design: All sensor compartments feature a sub-compartment design. A single malfunction will not impact the operation of other sensors. It is also equipped with an internal humidity detection and alarm function.
-
🔗
⑤ Strong Compatibility: Supports the development of future Luminsens sensor products.
Application
-
🌊
Environmental Monitoring: Ideal for rivers, lakes, and wastewater treatment plants to track pollution levels and compliance.
-
🐟
Aquaculture Management: Monitor dissolved oxygen and salinity for optimal aquatic health in fish farms.
-
🏭
Industrial Use: Deploy in marine engineering, oil pipelines, or chemical plants to ensure water quality meets safety standards.
Digital RS485 Water Quality Sensors Technical Data
| Parameter | Model | Range | Accuracy |
| DO sensor | LMS-DO10B | 0–20 mg/L, 0–60℃ | ±0.1–0.3 mg/L |
| DO sensor | LMS-DO10C | 0–20 mg/L, 0–60℃ | ±0.3 mg/L |
| Trace DO sensor | LMS-TDO100 | 0–2000 ppb, 0–50℃ | ±1 ppb |
| PH sensor | LMS-PH100 | 0–14 pH | ±0.02 pH |
| ORP sensor | LMS-ORP100 | ±1000.0 mV | ±0.2 mV |
| EC/TDS sensor | LMS-TDS102 | CT: 0–9999 uS/cm; 0–100 mS/cm TDS: 0–10000 ppm |
±2.5% FS |
| Salinity/EC/TDS sensor | LMS-SAL104 | Conductivity: 0.1–500 mS/cm TDS: 0–60000 ppm Salinity: 0–500.00 ppt |
±1.5% FS |
| COD sensor | LMS-COD100 | COD: 0.1–1500 mg/L TOC: 0.1–750 mg/L BOD: 0.1–900 mg/L Turbidity: 0.1–4000 NTU Temperature: 0–50℃ |
±5% equiv. KHP Temperature: ±0.5℃ |
| TSS sensor | LMS-TSS100 | 0–50000 mg/L / 0–120000 mg/L | ±10% FS or 10 mg/L |
| Turbidity sensor | LMS-TUR10L | 0–100 NTU | ±10% FS or 0.3 NTU |
| Turbidity sensor | LMS-TUR10H | 0–3000 NTU | ±10% FS or 0.3 NTU |
| CO2 sensor | LMS-CO2100 | 2000 PPM / 10000 PPM / 50000 PPM | ±5% FS |
| Ammonia Nitrogen sensor | LMS-NH4100 | 0–1000 mg/L | ±5% FS |
| Ion Selective sensor | LMS-ION100 | 0–1000 mg/L | ±5% FS |
| Oil in Water sensor | LMS-OIL100 | 0–50 mg/L; 0–5 mg/L | ±3% FS |
| Chlorophyll sensor | LMS-CHL100 | 0–500 ug/L | ±3% FS |
| Blue-Green Algae sensor | LMS-BGA100 | 0–2,000,000 cells/ml | ±3% FS |
| Residual Chlorine sensor | LMS-HCLO100 | 0–20.00 ppm | ±5% FS |
| Marine Current sensor | LMS-Current100 | Temperature: -3℃ – 45℃ Velocity of flow: 0–500 cm/s Flow direction: 0–359.9° |
±0.05℃ ±1 cm/s or ±2% ±2° |
Frequently Asked Questions (FAQ)
-
Q1: How many parameters can the Portable Multi-parameter Water Quality Analyzer measure simultaneously?The analyzer supports multiple parameters at once, including DO, pH, conductivity/EC, salinity, and turbidity. The universal platform allows Luminsens sensors to be freely inserted and automatically recognized, enabling flexible multi-parameter monitoring in a single device.
-
Q2: What communication protocol does the analyzer and its sensors support?Both the analyzer and its digital RS485 sensors support RS-485 communication with MODBUS protocol, making integration with industrial control systems and data loggers straightforward.
-
Q3: Can the cable length be customized for deeper water monitoring?Yes. The standard cable length is 5 meters, but it can be extended according to user requirements to accommodate various deployment depths and distances.
-
Q4: How is the analyzer powered in the field?The analyzer is powered by a rechargeable lithium battery with a 220V to DC charging adapter, making it suitable for portable field use. The sensors operate on DC 12~24V power supply.
-
Q5: Is the device suitable for harsh outdoor or industrial environments?Yes. The analyzer is built with polymer plastic housing and features a sub-compartment sensor design so that a single sensor malfunction does not affect others. It also includes an internal humidity detection and alarm function for added reliability. The operating temperature range is 0–50℃, with storage up to 85℃.
-
Q6: What types of water quality applications is this analyzer best suited for?The analyzer is ideal for environmental monitoring (rivers, lakes, wastewater treatment), aquaculture management (fish farms), and industrial applications such as marine engineering, oil pipelines, and chemical plants. Its wide range of compatible sensors makes it versatile across many water quality monitoring scenarios.